1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-239-7547

5950-00-239-7547

Power Transformer

Find complete technical information, availability, and procurement data for NSN 5950-00-239-7547 All details are based on official government and industry records to support accurate and compliant procurement.

5950-00-239-7547
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-239-7547
Item Name Code
32496
Assigment Date
10/31/1969 (56 years ago)

3.109 inches minimum and 3.141 inches maximum single mounting facility 2nd center group center to center distance between mounting facilities parallel to length, not established reliability indicator, 1.552 inches minimum and 1.572 inches maximum single mounting facility 4th center group center to center distance between mounting facilities parallel to length, 1.672 inches minimum and 1.704 inches maximum single mounting facility 2nd center group center to center distance between mounting facilities parallel to width, 3.109 inches minimum and 3.141 inches maximum single mounting facility 3rd center group center to center distance between mounting facilities parallel to length

Characteristics

Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
3.109 inches minimum and 3.141 inches maximum single mounting facility 2nd center group
Center To Center Distance Between Mounting Facilities Parallel To Length
3.109 inches minimum and 3.141 inches maximum single mounting facility 3rd center group
Center To Center Distance Between Mounting Facilities Parallel To Length
1.552 inches minimum and 1.572 inches maximum single mounting facility 4th center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.672 inches minimum and 1.704 inches maximum single mounting facility 2nd center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.672 inches minimum and 1.704 inches maximum single mounting facility 3rd center group
Center To Center Distance Between Mounting Facilities Parallel To Width
0.990 inches minimum and 1.010 inches maximum single mounting facility 4th center group
Overall Height
1.859 inches minimum and 1.891 inches maximum
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
three phase to single phase and three phase to three phase single component
Transformer Winding Connection Type
wye-delta
Winding Shielding Method
internal shield brought out to terminal single component
Body Length
3.859 inches minimum and 3.891 inches maximum
Body Width
2.172 inches minimum and 2.204 inches maximum
Maximum Operating Temp
170.0 celsius
Distance Between Mounting Facility Centers
1.109 inches minimum and 1.141 inches maximum single mounting facility 1st center group
Inclosure Type
fully inclosed
Mounting Facility Quantity
2 1st group
Mounting Facility Quantity
4 2nd group
Mounting Facility Quantity
4 3rd group
Mounting Facility Quantity
4 4th group
Mounting Method
threaded hole all groupings
Winding Function And Quantity
2 primary and 6 secondary single component
Nominal Thread Size
0.112 inches 2nd group
Nominal Thread Size
0.112 inches 3rd group
Nominal Thread Size
0.138 inches 1st group
Nominal Thread Size
0.164 inches 4th group
Winding Operating Current
600.0 milliamperes ac nominal single component 4th secondary
Winding Operating Current
40.0 milliamperes ac nominal single component 2nd secondary
Winding Operating Current
40.0 milliamperes ac nominal single component 3rd secondary
Winding Operating Current
84.0 milliamperes ac nominal single component 1st secondary
Winding Power Rating
41.52 volts-amperes single component 2nd secondary
Winding Power Rating
5.46 volts-amperes single component 1st secondary
Winding Power Rating
1.6 volts-amperes single component 3rd secondary
Winding Power Rating
1.8 volts-amperes single component 4th secondary
Winding Operating Voltage
1.038 ac kilovolts nominal single component 2nd secondary
Winding Operating Voltage
3.00 ac volts nominal single component 4th secondary
Winding Operating Voltage
65.00 ac volts nominal single component 1st secondary
Winding Operating Voltage
39.20 ac volts nominal single component 1st primary
Winding Operating Voltage
40.00 ac volts nominal single component 3rd secondary
Winding Operating Voltage
8.00 ac volts nominal single component 2nd primary
Special Features
two primary windings; six secondary windings
Test Data Document
04660-73c828 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
unc all groupings
Terminal Type And Quantity
25 turret

Related Parts & Specifications

This NSN includes a range of related parts designed for specific operational needs. Review each item below to find in-depth specifications, functional details, and guidance for correct application and replacement.

Part Number Name
73C828-004 Power Transformer

Classification Data

Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.

Type of Item Identification
1 - Full descriptive item identification
Demilitarization
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Criticality
X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Federal Item Identification Guide
A058B0
Precious Metals Indicator
A - Item does not contain precious metal.
Pseudo Item Name Code
0032496
Hazardous Material Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Freight Information

Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.

Major Organizational Entity
KE
National Motor Freight Classification Item Number
063420
National Motor Freight Classification Sub-Item Number
Z
Uniform Freight Classification Item Number
35355
National Motor Freight Class Rating
W - Rating variable
Water Commodity
595 - Transformer, (machinery and parts),(less than 35 feet)
Type of Cargo
Z - No special type of cargo code applicable
Special Hand
9 - Other or no special handling required (sh)
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity
HZ -
National Motor Freight Description
transformers,noi,or transformer par

FAQs

Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for 5950-00-239-7547

What is the FSCG of the NSN 5950-00-239-7547?
The FSCG of the NSN 5950-00-239-7547 is 5950
Does NSN 5950-00-239-7547 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-239-7547 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-00-239-7547 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-239-7547 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Fri, Oct 31, 1969

Need Consumables?

Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.

Electrical Wires

Recommended for You

Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.

Price & Availability

Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists:

FREE

Aviation Suppliers Association Member AS9120-ISO9001 Certification

Popular Parts

Browse our top-performing parts, selected based on customer demand and procurement frequency. All listings include up-to-date specs, availability, and condition:

26341-010
4930-01-126-7465
Lubricator
26341-016-00
5920-01-399-8672
Extractor Post Fuseholder
26341-020
4930-01-498-0352
Airline Lubricator
263410169
5962-01-474-3758
Memory Microcircuit
2634108
2915-00-931-5119
Fuel Control Roller Assembly
2634109
5310-00-938-4246
Special Nut
2634111
2915-00-931-5118
Fuel Control Lever
2634113
3120-00-984-7956
Sleeve Bushing
2634115
5340-00-984-7895
Helical Compression Spring Seat
2634125
5360-00-984-7896
Compression Helical Spring
263412889
5962-01-474-0726
Digital Microcircuit
2634132G001
5995-01-361-9885
E Special Purpose Cable Assembly
2634133
2540-01-670-0627
Vehicular Seat Frame
2634137
5305-00-936-0351
Machine Screw
263416
1420-01-693-4013
Guided Missile Access Cover