Electromagnetic Relay

9106-E1

9106-E1
(NSN) National Stock Number
5945-00-080-5275
Federal Supply Classification
5945 Relays and Solenoids
Item Name Code
32512
Schedule B Code
8536410020
Summary

2a single mounting facility thread class, 1.620 inches maximum overall length, 1.187 inches nominal single mounting facility center to center distance between mounting facilities parallel to length, 0.875 inches nominal single mounting facility center to center distance between mounting facilities parallel to width, 1.932 inches maximum overall height, 1.500 inches maximum overall width

DAC HCC DMIL RNCC
5 - - 5
RNVC SADC MSDS RNAAC
2 - - TX
Identification

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

INC FIIG Concept Condition
32512 A03300 1 1
Specifications
Thread Class
2a single mounting facility
Details A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.
Overall Length
1.620 inches maximum
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Center To Center Distance Between Mounting Facilities Parallel To Length
1.187 inches nominal single mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Center To Center Distance Between Mounting Facilities Parallel To Width
0.875 inches nominal single mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.
Overall Height
1.932 inches maximum
Details The distance measured in a straight line from the bottom to the top of an item.
Overall Width
1.500 inches maximum
Details An overall measurement taken at right angles to the length of an item,in distinction from thickness.
Environmental Protection
hermetic and salt spray resistant and shock resistant and vibration resistant
Details The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.
Winding Quantity
1
Details The number of individual /not electrically connected/ windings.
Coil Quantity
1
Details The number of coils included on the item.
Duty Type
continuous
Details Indicates the type of duty provided.
Mounting Facility Type And Quantity
4 threaded stud single mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Thread Quantity Per Inch
32 single mounting facility
Details The number of threads on the item per linear inch measured on a line parallel to the thread axis.
Nominal Thread Size
0.138 inches single mounting facility
Details A designation that is used for the purpose of general identification of the thread.
Mounting Facility Pattern
rectangular single mounting facility
Details The general configuration and relative position of the facilities provided for mounting the item.
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
Details The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.
Nominal Operating Current Rating And Type
100.0 milliamperes dc single winding
Details The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.
Time Delay
0.10 seconds nominal fixed operate time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Time Delay
0.50 seconds nominal fixed release time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
Details The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 milliamperes dc resistive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Maximum Voltage Rating In Volts
6.0 dc
Details The highest voltage at which the main contacts are rated for normal operation,expressed in volts.
Thread Series Designator
unc single mounting facility
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
8 wire hook all functions
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
10231797-4 18876 1 - 3 2 - TX
900064-68 93929 5 - 5 9 - TX
EPC11474-4 95692 5 - 5 9 - TX
EPC11474-4 0AGK2 5 - 5 2 - TX
92525-4 48313 5 - 5 2 - TX
92525-4 07031 5 - 5 9 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M P
RVC WCC TCC SHC
- 72D Z 9
Price and Availability Quote

Send us a quick request for quote using the form below:

Provided with every order

Order with confidence, we are a valued certified supplier serving customers in the military and aerospace industries.

  • Counterfeit Parts Prevention
  • 100% Product Inspections
  • 7 Year Record Retention
  • On Time Delivery
  • HAZMAT Certified
  • Worldwide Shipping
Manufacturer
TE CONNECTIVITY CORPORATION
CAGE: 89020
FAIRVIEW , NC , 28730-9168
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5945-00-080-5275
What is the NIIN of the NSN 5945-00-080-5275?
The National Item Identification Number (NIIN) of the NSN 5945-00-080-5275 is 00-080-5275
When the NSN 5945-00-080-5275 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Wed, Dec 6, 1967
Does the NSN 5945-00-080-5275 contain any precious metals?
Type/content is unknown
Does the NSN 5945-00-080-5275 contain any hazardous material?
No data in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At our core, we specialize in sourcing and supplying high-quality NSN (National Stock Number) parts to industries that demand precision and reliability.

From aerospace and defense to manufacturing and logistics, we provide the essential components that keep critical systems running.

Contact
350 Tenth Ave
San Diego, CA, 92101
United States
© 2025 National Stock Number (NSN) Parts Store, Inc. All rights reserved.
Made in USA