40887-2

Power Transformer

This page provides complete and verified information for part number 40887-2, NSN 5950-00-481-9294

You’ll find detailed technical specifications, product attributes, condition classification, and real-time stock availability. All data is based on official records and meets industry standards for defense, aerospace, and industrial sourcing. Whether you’re performing a parts audit, validating compliance, or preparing a purchase order, this part listing supports accurate and efficient procurement.

40887-2
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-481-9294
Item Name Code
32496
Assigment Date
03/14/1972 (54 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

1.250 inches maximum overall height, 10.0 kilohertz nominal single component frequency rating, 1.485 inches minimum and 1.515 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to length, not established reliability indicator, 1.485 inches minimum and 1.515 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to width

Characteristics

Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
1.485 inches minimum and 1.515 inches maximum single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.485 inches minimum and 1.515 inches maximum single mounting facility single center group
Overall Height
1.250 inches maximum
Frequency Rating
10.0 kilohertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Body Length
1.875 inches maximum
Body Width
1.875 inches maximum
Body Height
0.875 inches maximum
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded hole single group
Winding Function And Quantity
1 primary and 2 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.138 inches single group
Winding Operating Current
150.0 milliamperes ac maximum single component 1st secondary
Winding Operating Current
160.0 milliamperes ac maximum single component 2nd secondary
Winding Operating Voltage
110.00 ac volts nominal and 115.00 ac volts nominal and 120.00 ac volts nominal single component single primary
Winding Operating Voltage
40.00 ac volts nominal single component 1st secondary
Winding Operating Voltage
450.00 ac volts nominal single component 2nd secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
10 turret

Classification Data

Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.

Type of Item Identification
1 - Full descriptive item identification
Demilitarization
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Criticality
X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Federal Item Identification Guide
A058B0
Precious Metals Indicator
U - Precious metal content is unknown
Pseudo Item Name Code
0032496
Hazardous Material Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Freight Information

Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.

Major Organizational Entity
TX
National Motor Freight Classification Item Number
063420
National Motor Freight Classification Sub-Item Number
Z
Uniform Freight Classification Item Number
35355
National Motor Freight Class Rating
W - Rating variable
Water Commodity
595 - Transformer, (machinery and parts),(less than 35 feet)
Type of Cargo
Z - No special type of cargo code applicable
Special Hand
9 - Other or no special handling required (sh)
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity
HZ -
National Motor Freight Description
transformers,noi,or transformer par

FAQs

Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for 40887-2

What is the FSCG of the NSN 5950-00-481-9294?
The FSCG of the NSN 5950-00-481-9294 is 5950
Does NSN 5950-00-481-9294 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-481-9294 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-481-9294 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-481-9294 was assigned to the Federal Catalog?
It was assigned 54 years ago, on Tue, Mar 14, 1972

Need Consumables?

Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.

Electrical Wires

Recommended for You

Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.

Price & Availability

Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists:

FREE

Aviation Suppliers Association Member AS9120-ISO9001 Certification

Popular Parts

Browse our top-performing parts, selected based on customer demand and procurement frequency. All listings include up-to-date specs, availability, and condition:

TDA3189
2520-00-499-1214
Vehicular Shifter Fork
TDA3226-Q-1421
5340-01-518-8128
Dust and Moistu Protective Cover
TDA3361
2010-00-028-3942
Lever
TDA33M16T
5910-00-997-1184
Electrolytic Fixed Capacitor
TDA363
4020-00-153-4645
Fibrous Cord Assembly
TDA365
4720-00-300-0333
Air Duct Hose Assembly
TDA368
4020-00-153-4693
Fibrous Cord Assembly
TDA385
4720-00-786-5852
Air Duct Hose Assembly
TDA4600-2
5962-01-246-3159
Digital Microcircuit
TDA470M25T
5910-01-109-0611
Electrolytic Fixed Capacitor
TDA470M35
5910-01-117-8143
Electrolytic Fixed Capacitor
TDA470M35T
5910-01-117-8143
Electrolytic Fixed Capacitor
TDA470M50T
5910-01-273-5290
Electrolytic Fixed Capacitor
TDA47M25T
5910-01-098-2079
Electrolytic Fixed Capacitor
TDA4B
6636-01-631-7964
Environmental Testing Chamber