Circuit Breaker
W-C-375/10
Single pole type body style, 0.375 inches nominal mounting slot width, 6.310 inches nominal body length, 1.370 inches minimum and 1.380 inches maximum body width, 3.380 inches nominal body height, moderately rugged fragility factor
DAC | HCC | DMIL | RNCC |
---|---|---|---|
3 | - | - | 4 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
1 | - | - | TX |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
INC | FIIG | Concept | Condition |
---|---|---|---|
00136 | A030A0 | - | 1 |
Details
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.Details
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.Details
A measurement of the longest dimension of the body,in distinction from width.Details
A measurement taken at right angles to the length of the body,in distinction from thickness.Details
A measurement from the bottom to the top of the body,in distinction from depth.Details
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.Details
None.Details
The number of poles included in the item.Details
Indicates the type and number of facilities by which the item is mounted.Details
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.Details
The unusual or unique characteristic/s/ or quality/ies/ of an item which necessitates the establishment of a requirement for special handling.Details
The maximum current load that each pole is rated to carry continuously.Details
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.Details
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.Details
Indicates the type of electrical condition that will cause the device to trip.Details
The means by which the trip mechanism is released.Details
Denotes the type of trip release action.Details
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.Details
The means provided to reposition the mechanism so that the device is ready to function.Details
Indicates the type of mechanism provided for tripping main contacts.Details
Indicates the type and number of actuators provided for manual control.Details
Denotes the action imparted by actuator operation.Details
An indication of the designated position of the actuator.Details
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.Details
Indicates the type of protection for which the inclosure is designed.Details
The temperature of the medium surrounding the trip release at which it can be operated continuously.Details
The chemical compound or mechanical mixture properties of which the case is fabricated. please use mrc matt with isac table 0326 in place of this canceled mrc.Details
The cycles per second /hertz/ of the alternating current.Details
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.Details
Indicates the type and number of terminals for providing electrical connection.Details
The document designator of the specification or standard which established the item of supply.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
TE111010WL | 60969 | E | - | C | 1 | - | TX |
WC375/10-001 | 81348 | 3 | - | 2 | 2 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
P | U | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
35205 | - | W | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 72D | Z | 9 |
Provided with every order
Order with confidence, we are a valued certified supplier serving customers in the military and aerospace industries.
- Counterfeit Parts Prevention
- 100% Product Inspections
- 7 Year Record Retention
- On Time Delivery
- HAZMAT Certified
- Worldwide Shipping
What is the NIIN of the NSN 5925-00-004-7703?
When the NSN 5925-00-004-7703 was assigned to the Federal Catalog?
Does the NSN 5925-00-004-7703 contain any precious metals?
Does the NSN 5925-00-004-7703 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.