1.925 inches minimum and 1.955 inches maximum center to center distance between terminals parallel to length, 2.480 inches minimum and 2.500 inches maximum body length, 0.715 inches minimum and 0.745 inches maximum center to center distance between terminals parallel to width, 2.990 inches minimum and 3.010 inches maximum body width, multipole-multiple actuator type body style
Characteristics
Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.
- Body Style
- multipole-multiple actuator type
- Body Length
- 2.480 inches minimum and 2.500 inches maximum
- Body Width
- 2.990 inches minimum and 3.010 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 1.925 inches minimum and 1.955 inches maximum
- Center To Center Distance Between Terminals Parallel To Width
- 0.715 inches minimum and 0.745 inches maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 2.050 inches minimum and 2.070 inches maximum
- Switch Contact Arrangement
- single pole, double throw
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
- 0.715 inches minimum and 0.745 inches maximum
- Fragility Factor
- moderately rugged
- Boss Height
- 0.165 inches maximum
- Mounting Surface To Terminal End Distance
- 1.835 inches maximum
- Pole Quantity
- 4
- Arc Quenching Method
- magnetic blowout
- Mounting Facility Type And Quantity
- 8 threaded hole
- Storage Type
- general purpose warehouse
- Special Handling Feature
- magnetic
- Features Provided
- high inrush protection
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 100.0 milliamperes ac fourth location
- Maximum Continuous Load Current Rating Per Pole
- 72.0 amperes ac first location
- Maximum Continuous Load Current Rating Per Pole
- 72.0 amperes ac second location
- Maximum Continuous Load Current Rating Per Pole
- 72.0 amperes ac third location
- Operating Voltage Type And Rating Per Pole In Volts
- 240.0 ac all locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 5000.0 ac all locations
- Circuit Protection Type
- overcurrent all locations
- Trip Release Method
- magnetic-hydraulic all locations
- Trip Release Characteristic
- time delay all locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 all locations
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 4 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at each pole
- External Actuator Linkage Arrangement
- one, two, three, and four linked
- Auxiliary Switch Function And Quantity
- 1 alarm
- Internal Trip Release Configuration
- series trip all locations
- Nominal Thread Size
- 0.138 inches
- Switch Location And Position Designation
- internal at pole four
- Trip Delay Time In Seconds Per Rated Continuous Current
- 2.000 minimum at 200 pct and 22.000 maximum at 200 pct all locations
- Inclosure Protection Type For Which Designed
- corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant
- Switch Terminal Type
- quick disconnect, male
- Switch Current Rating And Type In Amps
- 10.0 ac and 3.0 dc
- Switch Voltage Rating And Type In Volts
- 250.0 ac and 50.0 dc
- Unpackaged Unit Weight
- 14.800 ounces nominal
- Frequency In Hertz
- 60.0 all locations
- Material
- plastic case
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 8 threaded stud
Related Parts & Specifications
This NSN includes a range of related parts designed for specific operational needs. Review each item below to find in-depth specifications, functional details, and guidance for correct application and replacement.
| Part Number | Name |
|---|---|
| 8560939-12 | Circuit Breaker |
| AM4-A8A8A8A9-A-72/72/72/0.1-20 | Circuit Breaker |
| APL-1111-1REC2-6588-12 | Circuit Breaker |
Classification Data
Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.
- Type of Item Identification
- Demilitarization
- Criticality
- Federal Item Identification Guide
- Precious Metals Indicator
- Pseudo Item Name Code
- Hazardous Material Indicator
- Schedule B Code
- 4 - Partial descriptive item identification (type 1 concept)
- A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
- X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
- A030A0
- A - Item does not contain precious metal.
- 0000136
- P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
- 8536200040
Freight Information
Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.
- Major Organizational Entity
- National Motor Freight Classification Item Number
- National Motor Freight Classification Sub-Item Number
- Uniform Freight Classification Item Number
- National Motor Freight Class Rating
- Water Commodity
- Type of Cargo
- Special Hand
- Air Dimension
- Air Commodity
- National Motor Freight Description
- TX
- 063160
- Z
- 35205
- W - Rating variable
- 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
- Z - No special type of cargo code applicable
- 9 - Other or no special handling required (sh)
- A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
- HZ -
- switch boxes/elec enclosures
FAQs
Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for 5925-01-123-2829
What is the FSCG of the NSN 5925-01-123-2829?
Does the NSN 5925-01-123-2829 have a Schedule B code assigned?
Does NSN 5925-01-123-2829 require demilitarization?
Does NSN 5925-01-123-2829 contain precious materials?
Does NSN 5925-01-123-2829 contain hazardous materials?
When the NSN 5925-01-123-2829 was assigned to the Federal Catalog?
Need Consumables?
Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.
Recommended for You
Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.
Price & Availability
Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists: