1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-044-0576

5925-01-044-0576

Circuit Breaker

Find complete technical information, availability, and procurement data for NSN 5925-01-044-0576 All details are based on official government and industry records to support accurate and compliant procurement.

5925-01-044-0576
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-044-0576
Item Name Code
00136
Assigment Date
07/07/1977 (49 years ago)

0.380 inches maximum bushing length, +0.3503 to 0.3537 inches thread pitch diameters, 1.562 inches maximum body length, 1.937 inches maximum body width, multipole-single actuator type body style

Characteristics

Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.562 inches maximum
Body Width
1.937 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.687 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.828 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac and 10.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and 500.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct and 0.950 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed and moisture resistant and vibration resistant and fungus resistant and shock resistant and salt spray proof
Unpackaged Unit Weight
150.0 grams nominal
Frequency In Hertz
400.0 all locations
Test Data Document
"81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unef
Terminal Type And Quantity
6 wire hook
Specification/Standard Data
81349-mil-c-39019/5 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially replaced by the NSN 5925-01-044-0576

NSN Name Date
5925-00-064-0166 No Name Available 04/01/1984
5925-00-152-7832 No Name Available 08/01/1988
5925-00-185-9358 No Name Available 10/01/1992
5925-00-479-1369 No Name Available 01/01/2009

Related Parts & Specifications

This NSN includes a range of related parts designed for specific operational needs. Review each item below to find in-depth specifications, functional details, and guidance for correct application and replacement.

Part Number Name
1945824-11 Circuit Breaker
260-4039-450 Circuit Breaker
7907117-10 Circuit Breaker
AP-MIL-112-1-7-1-103 Circuit Breaker
AP112-22A11 Circuit Breaker
HB3Z1-57 Circuit Breaker
M39010/05-248 Circuit Breaker
M39019/05-248 Circuit Breaker
M39019/5-57 Circuit Breaker

Classification Data

Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.

Type of Item Identification
4 - Partial descriptive item identification (type 1 concept)
Automatic Data Processing Point
0 - Represents items with no adp components
Demilitarization
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Criticality
X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Federal Item Identification Guide
A030A0
Precious Metals Indicator
A - Item does not contain precious metal.
Pseudo Item Name Code
0000136
Hazardous Material Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Schedule B Code
8536200040

Freight Information

Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.

Major Organizational Entity
TX
National Motor Freight Classification Item Number
063160
National Motor Freight Classification Sub-Item Number
Z
Uniform Freight Classification Item Number
35205
National Motor Freight Class Rating
W - Rating variable
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
Type of Cargo
Z - No special type of cargo code applicable
Special Hand
9 - Other or no special handling required (sh)
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity
HZ -
National Motor Freight Description
switch boxes/elec enclosures

FAQs

Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for 5925-01-044-0576

What is the FSCG of the NSN 5925-01-044-0576?
The FSCG of the NSN 5925-01-044-0576 is 5925
Does the NSN 5925-01-044-0576 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-044-0576 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-044-0576 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-044-0576 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-044-0576 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Thu, Jul 7, 1977

Need Consumables?

Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.

Electrical Wires

Recommended for You

Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.

Price & Availability

Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists:

FREE

Aviation Suppliers Association Member AS9120-ISO9001 Certification

Popular Parts

Browse our top-performing parts, selected based on customer demand and procurement frequency. All listings include up-to-date specs, availability, and condition:

G197E
4520-01-291-5797
Nonim Electrical Heating Element
G197M
1650-00-529-4477
Fluid Filter
G198
1325-00-025-3277
Bomb Igniter
G198-1
6210-00-350-2259
Panel Light
G1980-001
5330-00-400-8548
Gasket
G1981-3-12-2
5310-01-283-2695
Gang C Self-Locking Nut Assembly
G1981-3-6
5310-00-948-6322
Gang C Self-Locking Nut Assembly
G1981-3-6-3
5310-00-440-9906
Gang C Self-Locking Nut Assembly
G1981-3-6-96
5310-00-948-6322
Gang C Self-Locking Nut Assembly
G1981-3-8-2
5310-01-283-2696
Gang C Self-Locking Nut Assembly
G1981-3-8-4
5310-00-760-8035
Gang C Self-Locking Nut Assembly
G1981-3-8-5
5310-00-060-9795
Gang C Self-Locking Nut Assembly
G1981-4-12
5310-00-498-0611
Gang C Self-Locking Nut Assembly
G1981-4-8
5310-00-701-5252
Gang C Self-Locking Nut Assembly
G1981-4-9
5310-00-702-1481
Gang C Self-Locking Nut Assembly