Clinical Chemistry Analyzer NSN 6630-01-234-6794

Item Description

A microprocessor based instrument incorporating more than one method of analysis such as colorimetric and potentiometric/ion selective or kinetic enzyme. it may be either a stand-alone unit or modular in design. for instruments which have only one method of analysis see analyzer, as modified. excludes all instruments which employ a chromatographic method of analysis.

NSN 6630-01-234-6794 NSN: 6630-01-234-6794

  Provided with every order

  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

Get a Quote

Get an up to date price on nsn 6630012346794
Quantity
Email quote to
Phone Number
Company
Your Name
Privacy    Terms

Features and Characteristics

Current Type
Ac
Frequency Rating
Between 50.0 hertz and 60.0 hertz
Accessory Components And Quantity
Electro-optical magnification reader 1; work station 1; venous-blood pipetter 1
Universal Medical Device Nomenclature System Code
16298
Part Name Assigned By Controlling Agency
Analyzer, clinical chemistry
Exterior Container Weight
30.00 pounds
Voltage In Volts
120.0 and 220.0
Special Features
Microprocessor controlled electro-optical instrument for measuring packed cell volumes and converting to relative values; components inc.75x monocular microscope, rotating tube cartridge assembly; opical encoder; uv illuminator lamp; various lenses and filters to cause stained white cells and platelets to fluoresce; 12 place hematocrit centrifuge with head cover, fixed five minute timer; 12, 000 rpm speed capacity; and rcf of 14, 387 x g; two position pipetter with fixed volume of 111.1 microliters; work station with numbered slots for capillary tubes; wells for whole blood tubes and rack for storage of pipetter; operation method: electric; exterior container quantity: 1; the number of alternating current phase: two
Supplementary Features
Cont c/o two sealed calibration check tubes; one venous, one capillary; one pair forceps; spare pipetter "o" rings and grease, spare lamps fuses, two thrust pivots, one 5/64 in. Hex key and test guide; capable of performing the following quantitative functions on a centrifugal blood tube; hemoglobin, hematocrit, platelet count, white blood count, granulocyte count, and lymphocyte-monocyte count; for capillary microhematocrit tube kit order 6630-01-233-7594; for venous microhematocrit tube kit, order 6630-01-233-7593 and venous hematocrit tube kit 6630-01-233-9592; requisitioner should specify the voltage and frequency required
Unit Of Issue Weight
30.00 pounds
FSC
6630 Chemical Analysis Instruments
NIIN
012346794
NSN
6630012346794

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
6-0148P
Cage Code:
64616
Status:
A
MSDS:
Part Number:
428605
Cage Code:
4AZY5
Status:
A
MSDS:
Part Number:
4465
Cage Code:
12717
Status:
A
MSDS:
Part Number:
4466
Cage Code:
12717
Status:
A
MSDS:
Part Number:
4451 QBCII
Cage Code:
22790
Status:
A
MSDS:
Part Number:
6630-0284-0000
Cage Code:
99998
Status:
A
MSDS:
Part Number:
6630NCM162618
Cage Code:
64616
Status:
A
MSDS:
Part Number:
1397399
Cage Code:
88739
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 9027803200
  • NAICS: 334516
  • SITC: 87446
  • Description: Chemical analysis instruments and apparatus, nesoi
  • End Use (Code 21600):
    Laboratory testing instruments

Q & A

Frequently asked questions for NSN 6630-01-234-6794
What are the manufacturers of nsn 6630012346794?
Does this nsn 6630012346794 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 6630012346794
A microprocessor based instrument incorporating more than one method of analysis such as colorimetric and potentiometric/ion selective or kinetic enzyme. it may be either a stand-alone unit or modular in design. for instruments which have only one method of analysis see analyzer, as modified. excludes all instruments which employ a chromatographic method of analysis.
Does nsn 6630012346794 contain any precious metals?
No precious metal content.
Does nsn 6630012346794 contain any hazardous materials?
No MSDS. No hazardous material.
What is the ESD classification of nsn 6630012346794?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
42054
FIIG:
A503U0
App. Key:
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo