ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Oscilloscope NSN 6625-00-643-2277

Item Description

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

NSN 6625-00-643-2277 NSN: 6625-00-643-2277

  Provided with every order

  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

Get a Quote

Get an up to date price on nsn 6625006432277
Quantity
Email quote to
Phone Number
Company
Your Name
Privacy    Terms

Features and Characteristics

Overall Length
19.500 inches
Overall Height
13.500 inches
Overall Width
8.750 inches
Current Type
Ac
Frequency Rating
Between 50.0 hertz and 400.0 hertz
Accessory Components And Quantity
1 bezel, 1 filter color, 1 scale illuminated grandulated
Voltage Rating
Between 115.0 volts and 230.0 volts
Beam Quantity
1
Mounting Method
Table
Screen Size
5.000 in.
Sweep Circuits
Included
Generator Driven Feature
Not included
Sweep Circuit Type
Any acceptable
Sweep Frequency Range
+2.0/+30000.0 hertz
Single Trigger Sweep Duration
Between 0.5 seconds and 0.033 milliseconds
Trigger Sweep Voltage Amplitude Rating
180.0 volts
Trigger Sweep Polarity Switch
Included
Trigger Sweep Marker Intervals
Variable sweep
Expanded Sweep
Provided
Amplifier Deflection Sensitivity Provision
Provided
Vertical Deflection Sensitivity Voltage Rating
9.0 millivolts rms per inch
Horizontal Deflection Sensitivity Voltage Rating
100.0 millivolts any acceptable outside diameter
Input Intensity Modulation Feature
Not provided
Plate Direct Connection Deflection Sensitivity Provision
Provided
Direct Connection Vertical Deflection Sensitivity Voltage Rating
12.0 volts cw outside diameter and 14.0 volts peak outside diameter
Direct Connection Horizontal Deflection Sensitivity Voltage Rating
15.0 volts rms per inch and 18.0 volts rms per inch
Frequency Response Rating
Provided
X-axis Frequency Response Rating
Between 0.0 kilohertz and 100.0 kilohertz
Y-axis Frequency Response Rating
Between 0.0 kilohertz and 100.0 kilohertz
Amplifier Input Impedance Rating Provision
Provided
X-axis Input Impedance Rating
2.0 megohms
Y-axis Input Impedance Rating
2.0 megohms
Z-axis Input Impedance Rating
0.2 megohms
Calibrated Screen Scale
Not included
Trace Storage Tube
Not included
Camera Recording Device Accommodation
Not provided
Phase
Single
Reference Number Differentiating Characteristics
W/spares
FSC
6625 Electrical And Electronic Properties Measuring And Testing Instruments
NIIN
006432277
NSN
6625006432277

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
0S46U
Cage Code:
80058
Status:
A
MSDS:
Part Number:
1622K
Cage Code:
18778
Status:
A
MSDS:
Part Number:
304A
Cage Code:
18778
Status:
A
MSDS:
Part Number:
1622A
Cage Code:
72314
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 9030908030
  • NAICS: 334515
  • SITC: 87479
  • Description: Parts and accessories of articles of schedule b subheading 9030.39
  • End Use (Code 21160):
    Measuring, testing, control instruments

Q & A

Frequently asked questions for NSN 6625-00-643-2277
What are the manufacturers of nsn 6625006432277?
Does this nsn 6625006432277 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 6625006432277
A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. it can also be used to indicate any quantity which can be converted into terms of electrical potential. it may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. for items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). see also oscillograph.
Does nsn 6625006432277 contain any precious metals?
Precious metal content is unknown.
Does nsn 6625006432277 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 6625006432277?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00357
FIIG:
T320-G
App. Key:
GA
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo