ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-01-599-1976

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-01-599-1976 NSN: 5950-01-599-1976

Features and Characteristics

Reliability Indicator
Not established
Frequency Rating
50.0 hertz single component or 60.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Inclosure Type
Open
Mounting Method
Bracket single group
Winding Operating Current
2.08 amperes ac single component single secondary
Winding Operating Voltage
380.0 dry volts single component single primary or 415.0` dry volts single component single primary
Special Features
All leads are 18 awg stranded 2/64 inch insulation thickness. Standard parts have 12 inch total length, with 1/2 inch strip
Terminal Type And Quantity
2 wire lead
FSC
5950 Coils And Transformers
NIIN
015991976
NSN
5950015991976

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
1007247
Cage Code:
74924
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-01-599-1976
What are the manufacturers of nsn 5950015991976?
Does this nsn 5950015991976 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950015991976
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950015991976 contain any precious metals?
No precious metal content.
Does nsn 5950015991976 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950015991976?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo