ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-01-331-7786

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-01-331-7786 NSN: 5950-01-331-7786

Features and Characteristics

Reliability Indicator
Not established
Hazardous Locations/environmental Protection
Vibration resistant and humidity resistant
Overall Length
15.250 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
8.250 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
7.250 inches single mounting facility single center group
Overall Height
6.880 inches
Overall Width
8.630 inches
Mounting Slot Width
0.440 inches single group
Frequency Rating
50.0 hertz single component or 60.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Maximum Transformer Power Rating
5.0 kilovolt-ampere single component
Winding Shielding Method
Primary and secondary shielded and brought out to terminal single component
Maximum Operating Temp
130.0 degrees celsius
Inclosure Type
Fully enclosed
Mounting Facility Quantity
4 single group
Mounting Method
Slot single group
Winding Function And Quantity
2 primary single component and 2 secondary single component
Winding Operating Current
41.0 amperes ac single component all secondary
Winding Operating Voltage
120.00 ac volts single component all primary
Test Data Document
30003-1217as310 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
FSC
5950 Coils And Transformers
NIIN
013317786
NSN
5950013317786

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
1217AS310
Cage Code:
30003
Status:
A
MSDS:
Part Number:
HIT-5.0-13
Cage Code:
25965
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8504320000
  • NAICS: 334416
  • SITC: 77119
  • Description: Transformers, having a power handling capacity exceeding 1 kva but not exceeding 16 kva, nesoi
  • End Use (Code 20000):
    Generators, accessories

Q & A

Frequently asked questions for NSN 5950-01-331-7786
What are the manufacturers of nsn 5950013317786?
Does this nsn 5950013317786 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950013317786
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950013317786 contain any precious metals?
Precious metal content is unknown.
Does nsn 5950013317786 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950013317786?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo