Features and Characteristics
Reliability Indicator
Not established
Overall Length
Between 2.390 inches and 2.430 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
1.730 inches single mounting facility single center group and 1.770 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.410 inches single mounting facility single center group and 1.450 inches single mounting facility single center group
Overall Height
Between 5.068 inches and 5.088 inches
Overall Width
Between 2.117 inches and 2.217 inches
Mounting Slot Width
0.115 inches single group and 0.135 inches single group
Frequency Rating
400.0 hertz all components
Input-output Phase Relationship
Single phase to single phase all components
Maximum Transformer Power Rating
195.5 volt-ampere all components
Winding Shielding Method
Internal shield brought out to terminal all components
Maximum Operating Temp
104.0 degrees celsius
Inclosure Type
Fully enclosed
Mounting Facility Quantity
4 single group
Mounting Method
Slot single group
Rating Method
Electrical all components single primary
Winding Function And Quantity
1 primary 2nd component and 4 secondary 2nd component
Winding Operating Current
75.0 milliamperes ac 1st component 2nd secondary and 400.0 milliamperes ac 1st component 2nd secondary
Dc Resistance Rating In Ohms
7.800 1st component 2nd secondary
Winding Power Rating
45.824 volts-amperes 2nd component 1st secondary
Winding Operating Voltage
33.85 ac volts 1st component 2nd secondary and 38.30 ac volts 1st component 2nd secondary and 41.50 ac volts 1st component 2nd secondary and 70.90 ac volts 1st component 2nd secondary and 74.10 ac volts 1st component 2nd secondary and 78.55 ac volts 1st component 2nd secondary and 112.40 ac volts 1st component 2nd secondary
Test Data Document
16340-11-00151 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Terminal Type And Quantity
30 turret
FSC
5950 Coils And Transformers