ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-01-301-2614

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-01-301-2614 NSN: 5950-01-301-2614

Features and Characteristics

Reliability Indicator
Not established
Overall Length
Between 1.415 inches and 1.445 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
1.165 inches single mounting facility single center group and 1.195 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
0.975 inches single mounting facility single center group and 1.005 inches single mounting facility single center group
Overall Height
Between 1.255 inches and 1.285 inches
Mounting Hole Diameter
0.111 inches single group and 0.121 inches single group
Frequency Rating
400.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Maximum Transformer Power Rating
15.0 volt-ampere single component
Body Width
Between 1.225 inches and 1.255 inches
Maximum Operating Temp
130.0 degrees celsius
Inclosure Type
Fully enclosed
Mounting Facility Quantity
2 single group
Mounting Method
Unthreaded hole single group
Winding Function And Quantity
1 primary single component and 1 secondary single component
Winding Operating Current
600.0 milliamperes ac single component single secondary
Winding Operating Voltage
25.00 ac volts single component single secondary
Test Data Document
81349-mil-t-27 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity
5 turret
Specification Data
81349-mil-t-27/340 government specification
FSC
5950 Coils And Transformers
NIIN
013012614
NSN
5950013012614

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
M27/340-11
Cage Code:
81349
Status:
A
MSDS:
Part Number:
MIL-T-27/340
Cage Code:
81349
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8504314035
  • NAICS: 334416
  • SITC: 77119
  • Description: Transformers, having a power handling capacity less than 40 va, nesoi
  • End Use (Code 20000):
    Generators, accessories

Q & A

Frequently asked questions for NSN 5950-01-301-2614
What are the manufacturers of nsn 5950013012614?
Does this nsn 5950013012614 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950013012614
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950013012614 contain any precious metals?
No precious metal content.
Does nsn 5950013012614 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950013012614?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo