ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-01-244-8376

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-01-244-8376 NSN: 5950-01-244-8376

Features and Characteristics

Reliability Indicator
Not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.562 inches single mounting facili type 1st center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches single mounting facili type 1st center group
Frequency Rating
60.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Maximum Transformer Power Rating
321.1 volt-ampere single component
Winding Shielding Method
Internal shield brought out to terminal single component
Body Length
5.250 inches
Body Width
3.600 inches
Body Height
5.220 inches
Maximum Operating Temp
155.0 degrees celsius
Inclosure Type
Fully enclosed
Mounting Facility Quantity
4 all groupings
Mounting Method
Threaded hole all groupings
Winding Function And Quantity
1 primary single component and 2 secondary single component
Thread Size
0.190 inches all groupings
Winding Operating Current
3.0 amperes ac single component 2nd secondary
Winding Power Rating
220.0 volts-amperes single component 1st secondary
Criticality Code Justification
Zzzy
Winding Operating Voltage
33.70 ac volts single component 2nd secondary
Special Features
Item must comply with requirements of defense supply center columbus production standard no. Lo3542
Thread Series Designator
Unf all groupings
Terminal Type And Quantity
1 terminal block w/screws
Reference Number Differentiating Characteristics
Reference number differentiating material will be in accordance with naval inventory control point activity hx quality control. Manufacturing and testing specifications available at the dla icp
FSC
5950 Coils And Transformers
NIIN
012448376
NSN
5950012448376

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
KDW2301-1
Cage Code:
06RP6
Status:
A
MSDS:
Part Number:
LO3542
Cage Code:
16236
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8504314065
  • NAICS: 334416
  • SITC: 77119
  • Description: Transformers, having a power handling capacity 40 va or greater but less than 1 kva, nesoi
  • End Use (Code 20000):
    Generators, accessories

Q & A

Frequently asked questions for NSN 5950-01-244-8376
What are the manufacturers of nsn 5950012448376?
Does this nsn 5950012448376 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950012448376
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950012448376 contain any precious metals?
No precious metal content.
Does nsn 5950012448376 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950012448376?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo