ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-01-170-0534

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-01-170-0534 NSN: 5950-01-170-0534

Features and Characteristics

Reliability Indicator
Not established
Center To Center Distance Between Mounting Facilities Parallel To Length
4.375 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
3.750 inches single mounting facility single center group
Mounting Hole Diameter
0.210 inches single group
Frequency Rating
60.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Maximum Transformer Power Rating
350.0 kilovolt-ampere single component
Body Length
5.062 inches
Body Width
4.750 inches
Body Height
4.437 inches
Inclosure Type
Fully enclosed
Mounting Facility Quantity
4 single group
Mounting Method
Bracket single group and unthreaded hole single group
Winding Function And Quantity
1 primary single component and 3 secondary single component
Winding Operating Current
10.0 amperes ac single component 3rd secondary
Criticality Code Justification
Feat
Winding Operating Voltage
6.00 ac volts single component 3rd secondary
Special Features
Item must comply with requirements of defense supply center columbus production standard no. Lo3343
Terminal Type And Quantity
9 tab, solder lug
Reference Number Differentiating Characteristics
Reference number differentiating material will be in accordance with naval inventory control point activity hx quality control. Manufacturing and testing specifications available at the dla icp
FSC
5950 Coils And Transformers
NIIN
011700534
NSN
5950011700534

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
KBS2301-1
Cage Code:
06RP6
Status:
A
MSDS:
Part Number:
BX-8598
Cage Code:
85323
Status:
A
MSDS:
Part Number:
LO3343
Cage Code:
16236
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8504330040
  • NAICS: 335311
  • SITC: 77119
  • Description: Transformers, having a power handling capacity exceeding 50 kva but not exceeding 500 kva, nesoi
  • End Use (Code 20000):
    Generators, accessories

Q & A

Frequently asked questions for NSN 5950-01-170-0534
What are the manufacturers of nsn 5950011700534?
Does this nsn 5950011700534 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950011700534
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950011700534 contain any precious metals?
No precious metal content.
Does nsn 5950011700534 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950011700534?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo