Power Transformer NSN 5950-01-145-8828

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-01-145-8828 NSN: 5950-01-145-8828

Features and Characteristics

Reliability Indicator
Not established
Overall Length
2.312 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
1.688 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.438 inches single mounting facility single center group
Overall Height
2.938 inches
Overall Width
2.062 inches
Frequency Rating
60.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Winding Shielding Method
Internal shield grounded to core and mounting single component
Maximum Operating Temp
105.0 degrees celsius
Inclosure Type
Fully enclosed
Mounting Facility Quantity
4 single group
Mounting Method
Threaded stud single group
Winding Function And Quantity
1 primary single component and 1 secondary single component
Thread Size
0.138 inches single group
Winding Operating Current
2.0 amperes ac single component single secondary
Winding Operating Voltage
6.30 ac volts single component single secondary
Test Data Document
81349-mil-t-27 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator
Unc single group
Terminal Type And Quantity
6 tab, solder lug
Specification Data
81349-mil-t-27/300 government specification
FSC
5950 Coils And Transformers
NIIN
011458828
NSN
5950011458828

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
M27/300-0706
Cage Code:
81349
Status:
A
MSDS:
Part Number:
M27/300-07
Cage Code:
81349
Status:
A
MSDS:
Part Number:
MIL-PRF-27/300
Cage Code:
81349
Status:
A
MSDS:
Part Number:
A8405(521R)
Cage Code:
00144
Status:
A
MSDS:
Part Number:
WE1214
Cage Code:
26543
Status:
A
MSDS:
Part Number:
TF4RX01FB006
Cage Code:
81349
Status:
A
MSDS:
Part Number:
MS90020-2
Cage Code:
96906
Status:
A
MSDS:
Part Number:
MIL-T-27/35
Cage Code:
81349
Status:
A
MSDS:
Part Number:
TF4R03FB321
Cage Code:
81349
Status:
A
MSDS:
Part Number:
M27/35-01
Cage Code:
96906
Status:
A
MSDS:
Part Number:
MIL-T-27/300
Cage Code:
81349
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-01-145-8828
What are the manufacturers of nsn 5950011458828?
Does this nsn 5950011458828 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950011458828
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950011458828 contain any precious metals?
No precious metal content.
Does nsn 5950011458828 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950011458828?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo