Power Transformer NSN 5950-00-945-0650

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-945-0650 NSN: 5950-00-945-0650

Features and Characteristics

Reliability Indicator
Not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.734 inches single mounting facili type 2nd center group and 2.766 inches single mounting facili type 2nd center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.234 inches single mounting facili type 3rd center group and 2.266 inches single mounting facili type 3rd center group
Overall Height
Between 1.922 inches and 1.954 inches
Frequency Rating
400.0 hertz single component
Input-output Phase Relationship
Three phase to single phase single component and three phase to three phase single component
Transformer Winding Connection Type
Delta-wye
Winding Shielding Method
Internal shield brought out to terminal single component
Body Length
Between 3.609 inches and 3.641 inches
Body Width
Between 2.734 inches and 2.766 inches
Maximum Operating Temp
170.0 degrees celsius
Distance Between Mounting Facility Centers
2.234 inches single mounting facili type 1st center group and 2.266 inches single mounting facili type 1st center group
Inclosure Type
Fully enclosed
Mounting Facility Quantity
4 2nd group
Mounting Method
Threaded hole all groupings
Winding Function And Quantity
1 primary single component and 2 secondary single component
Thread Size
0.164 inches 4th group
Winding Operating Current
743.0 milliamperes ac single component 1st secondary
Winding Power Rating
29.13 volts-amperes single component 1st secondary
Winding Operating Voltage
6.50 ac volts single component 2nd secondary
Test Data Document
04660-73c828 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unc all groupings
Terminal Type And Quantity
13 turret
FSC
5950 Coils And Transformers
NIIN
009450650
NSN
5950009450650

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
8201425-001
Cage Code:
04660
Status:
A
MSDS:
Part Number:
73C828-001
Cage Code:
04660
Status:
A
MSDS:
Part Number:
172059-000
Cage Code:
81413
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-00-945-0650
What are the manufacturers of nsn 5950009450650?
Does this nsn 5950009450650 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950009450650
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950009450650 contain any precious metals?
No precious metal content.
Does nsn 5950009450650 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950009450650?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo