ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-00-932-6794

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-932-6794 NSN: 5950-00-932-6794

Features and Characteristics

Reliability Indicator
Not established
Center To Center Distance Between Mounting Facilities Parallel To Length
4.250 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
3.500 inches single mounting facility single center group
Frequency Rating
400.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Maximum Transformer Power Rating
284.4 volt-ampere single component
Winding Shielding Method
Internal shield grounded to core and brought out to terminal single component
Body Length
Between 4.870 inches and 5.000 inches
Body Width
Between 4.120 inches and 4.250 inches
Body Height
Between 4.620 inches and 4.750 inches
Maximum Operating Temp
130.0 degrees celsius
Inclosure Type
Hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
Threaded hole single group
Winding Function And Quantity
1 primary single component and 7 secondary single component
Thread Size
0.250 inches single group
Winding Operating Current
300.0 milliamperes ac single component 2nd secondary
Winding Power Rating
2.0 volts-amperes single component 2nd secondary
Winding Operating Voltage
6.50 ac volts single component 2nd secondary
Special Features
One primary winding; seven secondary windings with the 2nd and 7th winding center tapped and the 6th winding multiple tapped w/o center tap
Thread Series Designator
Unc single group
Terminal Type And Quantity
23 solder stud
FSC
5950 Coils And Transformers
NIIN
009326794
NSN
5950009326794

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
50385
Cage Code:
64053
Status:
A
MSDS:
Part Number:
722804-31
Cage Code:
05869
Status:
A
MSDS:
Part Number:
70245
Cage Code:
0LG51
Status:
A
MSDS:
Part Number:
7120
Cage Code:
05614
Status:
A
MSDS:
Part Number:
ST28850
Cage Code:
97102
Status:
A
MSDS:
Part Number:
TE12325
Cage Code:
54401
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8504314065
  • NAICS: 334416
  • SITC: 77119
  • Description: Transformers, having a power handling capacity 40 va or greater but less than 1 kva, nesoi
  • End Use (Code 20000):
    Generators, accessories

Q & A

Frequently asked questions for NSN 5950-00-932-6794
What are the manufacturers of nsn 5950009326794?
Does this nsn 5950009326794 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950009326794
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950009326794 contain any precious metals?
Precious metal content is unknown.
Does nsn 5950009326794 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950009326794?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo