ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-00-523-9478

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-523-9478 NSN: 5950-00-523-9478

  Provided with every order

  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

Get a Quote

Get an up to date price on nsn 5950005239478
Quantity
Email quote to
Phone Number
Company
Your Name
Privacy    Terms

Features and Characteristics

Reliability Indicator
Not establishednot established
Overall Height
Between 1.547 inches and 1.547 inches and 1.641 inches 1.641 inches
Frequency Rating
400.0 hertz single component400.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single componentsingle phase to single phase single component
Winding Shielding Method
Internal shield grounded to inclosure single componentinternal shield grounded to inclosure single component
Body Length
Between 1.500 inches and 1.500 inches and 1.531 inches 1.531 inches
Body Width
Between 1.500 inches and 1.500 inches and 1.531 inches 1.531 inches
Body Height
Between 1.297 inches and 1.297 inches and 1.391 inches 1.391 inches
Maximum Operating Temp
105.0 degrees celsius105.0 degrees celsius
Distance Between Mounting Facility Centers
1.352 inches single mounting facility single center group1.352 inches single mounting facility single center group
Inclosure Type
Fully enclosedfully enclosed
Mounting Facility Quantity
2 single group2 single group
Mounting Method
Threaded hole single groupthreaded hole single group
Winding Function And Quantity
1 primary single component and 1 primary single component and 2 secondary single component2 secondary single component
Thready Qty Per Inch (tpi)
40 single group
Thread Size
0.112 inches single group
Winding Operating Current
16.0 milliamperes ac single component single primary
Winding Operating Voltage
96.00 ac volts single component 2nd secondary72.00 ac volts single component 1st secondary
Special Test Features
Navord od41152
Thread Series Designator
Unc single group
Terminal Type And Quantity
8 wire hook
Reference Number Differentiating Characteristics
As differentiated by special test features
FSC
5950 Coils And Transformers
NIIN
005239478
NSN
5950005239478

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
334841
Cage Code:
56232
Status:
A
MSDS:
Part Number:
PEI 956
Cage Code:
13483
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-00-523-9478
What are the manufacturers of nsn 5950005239478?
Does this nsn 5950005239478 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950005239478
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950005239478 contain any precious metals?
Precious metal content is unknown.
Does nsn 5950005239478 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950005239478?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo