Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-510-1672 NSN: 5950-00-510-1672

Features and Characteristics

Reliability Indicator
Not establishednot established
Center To Center Distance Between Mounting Facilities Parallel To Length
5.063 inches single mounting facility single center group5.063 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
5.000 inches single mounting facility single center group5.000 inches single mounting facility single center group
Frequency Rating
62.0 hertz single component62.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single componentsingle phase to single phase single component
Winding Shielding Method
Internal shield grounded to inclosure and core single componentinternal shield grounded to inclosure and core single component
Body Length
6.000 inches 6.000 inches
Body Width
5.594 inches 5.594 inches
Body Height
4.625 inches 4.625 inches
Maximum Operating Temp
125.0 degrees celsius125.0 degrees celsius
Inclosure Type
Hermetically sealedhermetically sealed
Mounting Facility Quantity
6 single group6 single group
Winding Function And Quantity
2 primary single component and 2 primary single component and 3 secondary single component3 secondary single component
Thready Qty Per Inch (tpi)
32 single group32 single group
Thread Size
0.164 inches single group0.164 inches single group
Winding Operating Current
8.0 amperes ac single component 3rd secondary
Winding Operating Voltage
6.30 ac volts single component 3rd secondary25.20 ac volts single component 1st secondary
Thread Series Designator
Unc single group
Terminal Type And Quantity
12 tab, solder lug
FSC
5950 Coils And Transformers
NIIN
005101672
NSN
5950005101672

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
SMC248798
Cage Code:
80063
Status:
A
MSDS:
Part Number:
TF1SX03YY
Cage Code:
81349
Status:
A
MSDS:
Part Number:
27719
Cage Code:
73386
Status:
A
MSDS:
Part Number:
30-7296
Cage Code:
50508
Status:
A
MSDS:
Part Number:
59T11C1336
Cage Code:
59523
Status:
A
MSDS:
Part Number:
1500-0163
Cage Code:
04582
Status:
A
MSDS:
Part Number:
20164-2
Cage Code:
80089
Status:
A
MSDS:
Part Number:
A15055
Cage Code:
00144
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-00-510-1672
What are the manufacturers of nsn 5950005101672?
Does this nsn 5950005101672 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950005101672
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950005101672 contain any precious metals?
Precious metal content is unknown.
Does nsn 5950005101672 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950005101672?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo