A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-433-1961 NSN: 5950-00-433-1961

Features and Characteristics

Reliability Indicator
Not establishednot established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.735 inches single mounting facility single center group and 2.735 inches single mounting facility single center group and 2.765 inches single mounting facility single center group2.765 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.735 inches single mounting facility single center group and 1.735 inches single mounting facility single center group and 1.765 inches single mounting facility single center group1.765 inches single mounting facility single center group
Frequency Rating
400.0 hertz single component400.0 hertz single component
Input-output Phase Relationship
Three phase to six phase single componentthree phase to six phase single component
Transformer Winding Connection Type
Delta-wyedelta-wye
Winding Shielding Method
Internal shield grounded to inclosure and brought out to terminal single componentinternal shield grounded to inclosure and brought out to terminal single component
Body Length
3.750 inches 3.750 inches
Body Width
2.750 inches 2.750 inches
Body Height
2.125 inches 2.125 inches
Maximum Operating Temp
155.0 degrees celsius155.0 degrees celsius
Inclosure Type
Hermetically sealedhermetically sealed
Mounting Facility Quantity
4 single group4 single group
Mounting Method
Threaded hole single groupthreaded hole single group
Winding Function And Quantity
1 primary single component and 1 primary single component and 1 secondary single component1 secondary single component
Thread Size
0.138 inches single group0.138 inches single group
Winding Operating Current
1.83 amperes ac single component single secondary
Winding Power Rating
89.67 volts-amperes single component single secondary
Winding Operating Voltage
49.00 ac volts single component single secondary416.00 ac volts single component single primary
Thread Series Designator
Unc single group
Terminal Type And Quantity
11 turret
FSC
5950 Coils And Transformers
NIIN
004331961
NSN
5950004331961

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
161695
Cage Code:
3B150
Status:
A
MSDS:
Part Number:
10182074
Cage Code:
18876
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-00-433-1961
What are the manufacturers of nsn 5950004331961?
Does this nsn 5950004331961 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950004331961
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950004331961 contain any precious metals?
Precious metal content is unknown.
Does nsn 5950004331961 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950004331961?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A