Power Transformer NSN 5950-00-421-8356

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-421-8356 NSN: 5950-00-421-8356

Features and Characteristics

Reliability Indicator
Not establishednot established
Center To Center Distance Between Mounting Facilities Parallel To Length
8.490 inches single mounting facility single center group and 8.490 inches single mounting facility single center group and 8.510 inches single mounting facility single center group8.510 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
5.365 inches single mounting facility single center group and 5.365 inches single mounting facility single center group and 5.385 inches single mounting facility single center group5.385 inches single mounting facility single center group
Mounting Hole Diameter
0.282 inches single group and 0.282 inches single group and 0.344 inches single group0.344 inches single group
Frequency Rating
400.0 hertz single component400.0 hertz single component
Input-output Phase Relationship
Three phase to six phase single componentthree phase to six phase single component
Transformer Winding Connection Type
Delta-wyedelta-wye
Winding Shielding Method
Internal shield brought out to terminal single componentinternal shield brought out to terminal single component
Body Length
10.060 inches 10.060 inches
Body Width
7.560 inches 7.560 inches
Body Height
5.500 inches 5.500 inches
Maximum Operating Temp
130.0 degrees celsius130.0 degrees celsius
Inclosure Type
Fully enclosedfully enclosed
Mounting Facility Quantity
4 single group4 single group
Mounting Method
Unthreaded hole single groupunthreaded hole single group
Winding Function And Quantity
1 primary single component and 1 primary single component and 2 secondary single component2 secondary single component
Winding Operating Current
2.5 amperes ac single component 2nd secondary and 16.3 amperes ac single component 2nd secondary
Winding Power Rating
499.8 volts-amperes single component 1st secondary
Winding Operating Voltage
8.15 ac volts single component 2nd secondary and 29.00 ac volts single component 1st secondary and 13.20 ac volts single component 2nd secondary34.00 ac volts single component 1st secondary
Terminal Type And Quantity
30 threaded stud
FSC
5950 Coils And Transformers
NIIN
004218356
NSN
5950004218356

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
429-5072-001
Cage Code:
97871
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-00-421-8356
What are the manufacturers of nsn 5950004218356?
Does this nsn 5950004218356 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950004218356
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950004218356 contain any precious metals?
Precious metal content is unknown.
Does nsn 5950004218356 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950004218356?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo