ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-00-324-2971

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-324-2971 NSN: 5950-00-324-2971

Features and Characteristics

Reliability Indicator
Not establishednot established
Hazardous Locations/environmental Protection
Moisture resistant and oil resistant and salt spray resistant and vibration resistant
Center To Center Distance Between Mounting Facilities Parallel To Length
1.433 inches single mounting facility single center group and 1.433 inches single mounting facility single center group and 1.443 inches single mounting facility single center group1.443 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.401 inches single mounting facility single center group and 1.401 inches single mounting facility single center group and 1.411 inches single mounting facility single center group1.411 inches single mounting facility single center group
Overall Height
3.000 inches 3.000 inches
Frequency Rating
380.0 hertz single component and 380.0 hertz single component and 420.0 hertz single component420.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single componentsingle phase to single phase single component
Winding Shielding Method
Core grounded single componentcore grounded single component
Body Length
2.750 inches 2.750 inches
Body Width
2.000 inches 2.000 inches
Maximum Operating Temp
85.0 degrees celsius85.0 degrees celsius
Inclosure Type
Fully enclosedfully enclosed
Mounting Facility Quantity
4 single group4 single group
Mounting Method
Threaded hole single groupthreaded hole single group
Winding Function And Quantity
1 primary single component and 1 primary single component and 1 secondary single component1 secondary single component
Thread Size
0.138 inches single group0.138 inches single group
Winding Operating Current
4.5 amperes ac single component single secondary and 12.0 amperes ac single component single secondary
Winding Operating Voltage
115.00 ac volts single component single primary5.30 ac volts single component single secondary5.30 ac volts single component single secondary
Test Data Document
99971-7637677+1 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unc single group
Terminal Type And Quantity
4 tab, solder lug
FSC
5950 Coils And Transformers
NIIN
003242971
NSN
5950003242971

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
GE-704-P
Cage Code:
20950
Status:
A
MSDS:
Part Number:
7637677P0001
Cage Code:
99971
Status:
A
MSDS:
Part Number:
7637677P1
Cage Code:
99971
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-00-324-2971
What are the manufacturers of nsn 5950003242971?
Does this nsn 5950003242971 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950003242971
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950003242971 contain any precious metals?
Precious metal content is unknown.
Does nsn 5950003242971 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950003242971?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo