ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Power Transformer NSN 5950-00-250-0561

Item Description

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

NSN 5950-00-250-0561 NSN: 5950-00-250-0561

Features and Characteristics

Overall Length
3.875 inches 3.875 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
2.990 inches single mounting facility single center group and 2.990 inches single mounting facility single center group and 3.010 inches single mounting facility single center group3.010 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.365 inches single mounting facility single center group and 1.365 inches single mounting facility single center group and 1.385 inches single mounting facility single center group1.385 inches single mounting facility single center group
Overall Height
3.083 inches 3.083 inches
Overall Width
2.063 inches 2.063 inches
Frequency Rating
400.0 hertz single component400.0 hertz single component
Input-output Phase Relationship
Three phase to single phase single component and three phase to single phase single component and three phase to three phase single componentthree phase to three phase single component
Winding Shielding Method
Internal shield grounded to inclosure and brought out to terminal single componentinternal shield grounded to inclosure and brought out to terminal single component
Body Length
3.875 inches 3.875 inches
Body Width
2.063 inches 2.063 inches
Body Height
2.313 inches 2.313 inches
Inclosure Type
Hermetically sealedhermetically sealed
Mounting Facility Quantity
4 single group4 single group
Mounting Method
Threaded stud single groupthreaded stud single group
Winding Function And Quantity
1 primary single component and 1 primary single component and 2 secondary single component2 secondary single component
Thready Qty Per Inch (tpi)
32 single group32 single group
Thread Size
0.190 inches single group0.190 inches single group
Winding Operating Current
500.0 milliamperes ac single component 1st secondary
Winding Operating Voltage
50.00 ac volts single component 1st secondary
Thread Series Designator
Unf single group
Terminal Type And Quantity
11 turret
FSC
5950 Coils And Transformers
NIIN
002500561
NSN
5950002500561

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
151-265-0001
Cage Code:
95542
Status:
A
MSDS:
Part Number:
TW63315
Cage Code:
02640
Status:
A
MSDS:

Q & A

Frequently asked questions for NSN 5950-00-250-0561
What are the manufacturers of nsn 5950002500561?
Does this nsn 5950002500561 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5950002500561
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). it may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. for transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. excludes transformer (1), pulse.
Does nsn 5950002500561 contain any precious metals?
No precious metal content.
Does nsn 5950002500561 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5950002500561?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
32496
FIIG:
A058B0
App. Key:
J
Cond. Code:
2
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo