ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Circuit Breaker NSN 5925-01-591-6139

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-591-6139 NSN: 5925-01-591-6139

Features and Characteristics

Body Style
Multipole-multiple actuator type
Body Length
105.0 millimeters
Body Width
53.1 millimeters
Body Height
44.0 millimeters
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Width
17.7 millimeters
End Application
Aircraft c295
Boss Height
16.0 millimeters
Pole Quantity
3
Mounting Facility Type And Quantity
Din rail
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations and 10.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac all locations and 480.0 ac all locations and 96.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations and 10000.0 dc all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
1000.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one and at pole two and at pole three
External Actuator Linkage Arrangement
One, two, and three linked
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 800 pct pascal all locations and 90.000 18 stage pascal all locations
Part Name Assigned By Controlling Agency
Faz na branch circuit breaker type d for highly inductive load
Special Features
Suitable for applications where high levels of inrush current are expected; prevents nuisance tripping in high inductive apps
Frequency In Hertz
50.0 all locations or 60.0 all locations
Terminal Type And Quantity
6 screw
FSC
5925 Circuit Breakers
NIIN
015916139
NSN
5925015916139

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
FAZ-D10/3-NA
Cage Code:
76526
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-591-6139
What are the manufacturers of nsn 5925015916139?
Does this nsn 5925015916139 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925015916139
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925015916139 contain any precious metals?
No precious metal content.
Does nsn 5925015916139 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925015916139?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo