Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-313-3895 NSN: 5925-01-313-3895

Features and Characteristics

Body Style
Multipole-multiple actuator type
Bushing Length
Between 0.235 inches and 0.250 inches
Body Length
Between 2.406 inches and 2.468 inches
Body Width
2.189 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 1.406 inches and 1.468 inches
Center To Center Distance Between Terminals Parallel To Width
Between 1.045 inches and 1.075 inches
Unthreaded Mounting Hole Diameter
0.140 inches
Switch Contact Arrangement
Single pole, double throw
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
Between 2.219 inches and 2.249 inches
Pole Quantity
3
Mounting Facility Type And Quantity
6 unthreaded hole
Storage Type
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations and 150.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 30.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations and 3000.0 dc all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Thermal all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
3 push button
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, and three linked
Auxiliary Switch Function And Quantity
3 alarm
Internal Trip Release Configuration
Series trip all locations
Switch Location And Position Designation
Internal at each pole
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct all locations and 70.000 at 200 pct all locations
Inclosure Protection Type For Which Designed
Vibration resistant and shock resistant
Trip Release Ambient Tempurature Rating
25.0 degrees celsius all locations
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
100.0 ac and 100.0 dc
Switch Voltage Rating And Type In Volts
120.0 ac and 28.0 dc
Frequency In Hertz
400.0 all locations
Unpackaged Unit Weight
130.0 grams
Terminal Type And Quantity
6 tab w/screw
FSC
5925 Circuit Breakers
NIIN
013133895
NSN
5925013133895

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
970-002-150
Cage Code:
76374
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-313-3895
What are the manufacturers of nsn 5925013133895?
Does this nsn 5925013133895 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925013133895
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925013133895 contain any precious metals?
No precious metal content.
Does nsn 5925013133895 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925013133895?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo