Circuit Breaker NSN 5925-01-302-8954

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-302-8954 NSN: 5925-01-302-8954

Features and Characteristics

Thread Pitch Diameters
+0.1177/+0.1214 inches
Body Style
Single pole type
Body Length
2.000 inches
Body Width
0.750 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.530 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches
Fragility Factor
Moderately rugged
Boss Height
0.130 inches
Mounting Surface To Terminal End Distance
2.000 inches
Pole Quantity
1
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
6.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic-hydraulic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.200 at 200 pct single location
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant
Special Features
Actuator white with black markings
Unpackaged Unit Weight
2.200 ounces
Thread Series Designator
Unc
Terminal Type And Quantity
2 quick disconnect, male
FSC
5925 Circuit Breakers
NIIN
013028954
NSN
5925013028954

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
APG-1-1-51-602-91
Cage Code:
81541
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-302-8954
What are the manufacturers of nsn 5925013028954?
Does this nsn 5925013028954 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925013028954
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925013028954 contain any precious metals?
No precious metal content.
Does nsn 5925013028954 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925013028954?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo