A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-295-0612 NSN: 5925-01-295-0612

Features and Characteristics

Body Style
Multipole-single actuator type
Bushing Length
Between 0.464 inches and 0.526 inches
Body Length
Between 1.969 inches and 2.031 inches
Body Width
1.515 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 1.499 inches and 1.561 inches
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches
Nonturn Device Location
At 9 oclock and at 12 oclock
Nonturn Device Radius
Between 0.641 inches and 0.671 inches
Nonturn Device Length
Between 0.115 inches and 0.145 inches
Nonturn Device Diameter
0.138 inches
Switch Contact Arrangement
Single pole, double throw
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
2.232 inches
Pole Quantity
2
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.500 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.160 at 200 pct all locations and 1.600 at 200 pct all locations
Inclosure Protection Type For Which Designed
Fungus resistant
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
60.0 all locations
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator
Un
Terminal Type And Quantity
4 tab w/screw
Specification Data
81349-mil-c-55629/21 government specification
FSC
5925 Circuit Breakers
NIIN
012950612
NSN
5925012950612

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
M55629/21FNFN
Cage Code:
81349
Status:
A
MSDS:
Part Number:
MIL-C-55629/21
Cage Code:
81349
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-295-0612
What are the manufacturers of nsn 5925012950612?
Does this nsn 5925012950612 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925012950612
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925012950612 contain any precious metals?
Precious metal content is unknown.
Does nsn 5925012950612 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925012950612?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo