ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Circuit Breaker NSN 5925-01-216-0285

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-216-0285 NSN: 5925-01-216-0285

Features and Characteristics

Body Style
Multipole-single actuator type
Bushing Length
0.390 inches
Body Length
1.562 inches
Body Width
1.281 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.885 inches
Center To Center Distance Between Terminals Parallel To Width
0.625 inches
Switch Contact Arrangement
Single pole, double throw
Mounting Surface To Terminal End Distance
1.780 inches
Pole Quantity
2
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
4.0 amperes dc second location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc second location
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
Between pole one and two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Relay trip second location
Thread Size
0.375 inches
Switch Location And Position Designation
Internal at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 at 200 pct and 4.500 at 200 pct first location
Inclosure Protection Type For Which Designed
Hermetically sealed
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
1.0 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
Frequency In Hertz
60.0 first location
Thread Series Designator
Unef
Terminal Type And Quantity
4 wire hook and 2 tab, solder lug
FSC
5925 Circuit Breakers
NIIN
012160285
NSN
5925012160285

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
G612834-2
Cage Code:
01714
Status:
A
MSDS:
Part Number:
AP41-1R-5157-2
Cage Code:
81541
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-216-0285
What are the manufacturers of nsn 5925012160285?
Does this nsn 5925012160285 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925012160285
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925012160285 contain any precious metals?
No precious metal content.
Does nsn 5925012160285 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925012160285?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo