Circuit Breaker NSN 5925-01-199-9041

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-199-9041 NSN: 5925-01-199-9041

Features and Characteristics

Bushing Length
0.380 inches
Body Length
1.562 inches
Body Width
1.875 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.875 inches
Center To Center Distance Between Terminals Parallel To Width
0.625 inches
Nonturn Device Location
At 3 oclock and at 9 oclock
Nonturn Device Radius
0.625 inches
Nonturn Device Length
0.130 inches
Nonturn Device Diameter
0.140 inches
Switch Contact Arrangement
Single pole, double throw
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches
Pole Quantity
3
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.375 inches
Switch Location And Position Designation
Internal at pole three
Inclosure Protection Type For Which Designed
Hermetically sealed
Switch Terminal Type
Pin
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
Frequency In Hertz
50.0 all locations or 60.0 all locations
Thread Series Designator
Unef
Terminal Type And Quantity
6 wire hook
FSC
5925 Circuit Breakers
NIIN
011999041
NSN
5925011999041

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
AP-112-1R-69-502
Cage Code:
81541
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-199-9041
What are the manufacturers of nsn 5925011999041?
Does this nsn 5925011999041 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925011999041
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925011999041 contain any precious metals?
No precious metal content.
Does nsn 5925011999041 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925011999041?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo