Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-144-9134 NSN: 5925-01-144-9134

Features and Characteristics

Body Style
Multipole-single actuator type
Body Length
6.500 inches
Body Width
4.125 inches
Body Height
3.875 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
3.937 inches
Center To Center Distance Between Terminals Parallel To Width
1.375 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.312 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.687 inches
End Application
T-1434/wqc
Boss Height
0.187 inches
Pole Quantity
3
Mounting Facility Type And Quantity
4 threaded stud
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Features Provided
Adjustable trip release
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations and 15.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations and 10000.0 dc all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Auxiliary Switch Function And Quantity
1 alarm
Adjustable Trip Setting Current Range Per Pole In Amps
+75.0/+101.0 ac all locations and +180.0/+210.0 dc all locations
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.190 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
3600.000 at 150 pct all locations
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
15.0 ac
Switch Voltage Rating And Type In Volts
250.0 ac
Frequency In Hertz
60.0 all locations
Thread Series Designator
Unf
Terminal Type And Quantity
6 threaded stud
FSC
5925 Circuit Breakers
NIIN
011449134
NSN
5925011449134

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
3168700PC1
Cage Code:
53711
Status:
A
MSDS:
Part Number:
3168700-1
Cage Code:
10001
Status:
A
MSDS:
Part Number:
58E-6597
Cage Code:
89946
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-144-9134
What are the manufacturers of nsn 5925011449134?
Does this nsn 5925011449134 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925011449134
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925011449134 contain any precious metals?
No precious metal content.
Does nsn 5925011449134 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925011449134?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo