ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Circuit Breaker NSN 5925-01-139-3140

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-139-3140 NSN: 5925-01-139-3140

Features and Characteristics

Body Length
11.000 inches
Body Width
9.000 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
9.875 inches
Center To Center Distance Between Terminals Parallel To Width
3.000 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.875 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches
Fragility Factor
Moderately rugged
Boss Height
0.250 inches
Mounting Surface To Terminal End Distance
9.281 inches
Pole Quantity
3
Arc Quenching Method
Air
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
General purpose warehouse
Features Provided
Adjustable trip release
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac all locations and 250.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac second location and 250.0 dc second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
20000.0 ac second location and 15000.0 dc second location
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Adjustable Trip Setting Current Range Per Pole In Amps
+910.0/+1560.0 ac third location
Internal Trip Release Configuration
Shunt trip third location
Thread Size
0.250 inches
Frequency In Hertz
60.0 third location
Thread Series Designator
Unc
Terminal Type And Quantity
6 threaded stud
FSC
5925 Circuit Breakers
NIIN
011393140
NSN
5925011393140

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
ETN583100S36
Cage Code:
30086
Status:
A
MSDS:
Part Number:
315C574G18 WITH 452D377G17
Cage Code:
89946
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-139-3140
What are the manufacturers of nsn 5925011393140?
Does this nsn 5925011393140 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925011393140
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925011393140 contain any precious metals?
No precious metal content.
Does nsn 5925011393140 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925011393140?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo