Circuit Breaker NSN 5925-01-108-4264

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-108-4264 NSN: 5925-01-108-4264

  Provided with every order

  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

Get a Quote

Get an up to date price on nsn 5925011084264
Quantity
Email quote to
Phone Number
Company
Your Name
Privacy    Terms

Features and Characteristics

Overall Length
1.700 inches
Overall Width
0.550 inches
Bushing Length
Between 0.183 inches and 0.193 inches
Body Length
1.700 inches
Body Width
0.550 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.450 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.640 inches
Fragility Factor
Moderately rugged
Boss Height
0.120 inches
Mounting Surface To Terminal End Distance
1.120 inches
Pole Quantity
1
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
2 clip
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Maximum Continuous Load Current Rating Per Pole
1.8 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal-magnetic single location
Trip Release Characteristic
Instantaneous single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Inclosure Protection Type For Which Designed
Vibration resistant and humidity resistant and corrosion resistant and hermetically sealed
Trip Release Ambient Tempurature Rating
65.0 degrees celsius single location
Frequency In Hertz
60.0 single location
Test Data Document
67177-85-1491 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Terminal Type And Quantity
2 quick disconnect, male
FSC
5925 Circuit Breakers
NIIN
011084264
NSN
5925011084264

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
85-1491-06
Cage Code:
67177
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-108-4264
What are the manufacturers of nsn 5925011084264?
Does this nsn 5925011084264 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925011084264
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925011084264 contain any precious metals?
No precious metal content.
Does nsn 5925011084264 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925011084264?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo