ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Circuit Breaker NSN 5925-01-092-9694

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-092-9694 NSN: 5925-01-092-9694

Features and Characteristics

Body Style
Single pole type
Overall Length
3.160 inches
Body Width
1.880 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.060 inches
Unthreaded Mounting Hole Diameter
Between 0.195 inches and 0.225 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
2.000 inches
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole
90.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
Automatic
Internal Trip Release Configuration
Series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 at 200 pct single location and 50.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Vibration resistant and shock resistant and salt spray proof and fungus resistant
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Terminal Type And Quantity
2 threaded stud
Specification Data
58536-aa55571/07-008 government specification
FSC
5925 Circuit Breakers
NIIN
010929694
NSN
5925010929694

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
AA55571/07-008
Cage Code:
58536
Status:
A
MSDS:
Part Number:
A-A-55571/7
Cage Code:
58536
Status:
A
MSDS:
Part Number:
PDLA-90
Cage Code:
82647
Status:
A
MSDS:
Part Number:
M13516/7-8
Cage Code:
81349
Status:
A
MSDS:
Part Number:
MIL-C-13516/7
Cage Code:
81349
Status:
A
MSDS:
Part Number:
M13516/7BII-90
Cage Code:
81349
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-092-9694
What are the manufacturers of nsn 5925010929694?
Does this nsn 5925010929694 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925010929694
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925010929694 contain any precious metals?
Precious metal content is unknown.
Does nsn 5925010929694 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925010929694?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo