ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Circuit Breaker NSN 5925-00-833-7947

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-833-7947 NSN: 5925-00-833-7947

Features and Characteristics

Body Style
Single pole type
Body Length
6.312 inches
Body Width
1.375 inches
Body Height
3.375 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
5.225 inches
Unthreaded Mounting Hole Diameter
0.190 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.875 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.688 inches
Boss Height
0.188 inches
Pole Quantity
1
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location and 30.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 125.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac single location and 5000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal-magnetic single location
Trip Release Characteristic
Instantaneous single location and time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 at 200 pct single location and 150.000 at 200 pct single location
Inclosure Protection Type For Which Designed
General purpose
Trip Release Ambient Tempurature Rating
40.0 degrees celsius single location
Frequency In Hertz
60.0 single location
Terminal Type And Quantity
2 compression
FSC
5925 Circuit Breakers
NIIN
008337947
NSN
5925008337947

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
TEB111030
Cage Code:
60969
Status:
A
MSDS:
Part Number:
TE11030
Cage Code:
60969
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-833-7947
What are the manufacturers of nsn 5925008337947?
Does this nsn 5925008337947 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925008337947
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925008337947 contain any precious metals?
Precious metal content is unknown.
Does nsn 5925008337947 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925008337947?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo