A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-807-9290 NSN: 5925-00-807-9290

Features and Characteristics

Body Style
Single pole type
Body Length
Between 2.485 inches and 2.515 inches
Body Width
Between 0.735 inches and 0.765 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 1.925 inches and 1.955 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.047 inches and 2.077 inches
Switch Contact Arrangement
Single pole, double throw
Fragility Factor
Moderately rugged
Boss Height
Between 0.125 inches and 0.155 inches
Mounting Surface To Terminal End Distance
Between 2.775 inches and 2.955 inches
Pole Quantity
1
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
250.0 milliamperes ac single location and 250.0 milliamperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 2000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip single location
Thread Size
0.138 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 at 200 pct single location and 10.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant and moisture resistant and salt spray proof
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
115.0 ac and 50.0 dc
Frequency In Hertz
60.0 single location
Unpackaged Unit Weight
0.312 pounds
Test Data Document
05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unc
Terminal Type And Quantity
2 threaded stud
FSC
5925 Circuit Breakers
NIIN
008079290
NSN
5925008079290

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
711570-26REVC
Cage Code:
05869
Status:
A
MSDS:
Part Number:
315C816G04
Cage Code:
79500
Status:
A
MSDS:
Part Number:
70-132-3MG6
Cage Code:
74193
Status:
A
MSDS:
Part Number:
AM12HKMG3-0-25-50-250VAC4
Cage Code:
74193
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-807-9290
What are the manufacturers of nsn 5925008079290?
Does this nsn 5925008079290 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925008079290
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925008079290 contain any precious metals?
No precious metal content.
Does nsn 5925008079290 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925008079290?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo