Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-755-5081 NSN: 5925-00-755-5081

Features and Characteristics

Body Style
Multipole-multiple actuator type
Body Length
5.250 inches
Body Width
4.500 inches
Body Height
2.687 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
4.359 inches
Center To Center Distance Between Terminals Parallel To Width
0.984 inches
Unthreaded Mounting Hole Diameter
0.190 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.062 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.984 inches
Fragility Factor
Moderately rugged
Boss Height
0.218 inches
Pole Quantity
3
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
12 threaded hole and 12 unthreaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
416.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Ultimate Trip Time Per Pole In Seconds
2.000 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, and three linked
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.164 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct all locations and 0.200 at 300 pct all locations
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
Frequency In Hertz
400.0 all locations
Thread Series Designator
Unc
Terminal Type And Quantity
6 threaded stud
FSC
5925 Circuit Breakers
NIIN
007555081
NSN
5925007555081

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
9081267
Cage Code:
18876
Status:
A
MSDS:
Part Number:
64-964BMG4-4AMP
Cage Code:
74193
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-755-5081
What are the manufacturers of nsn 5925007555081?
Does this nsn 5925007555081 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925007555081
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925007555081 contain any precious metals?
Precious metal content is unknown.
Does nsn 5925007555081 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925007555081?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo