Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-449-1674 NSN: 5925-00-449-1674

Features and Characteristics

Body Style
Multipole-multiple actuator type
Body Length
2.500 inches
Body Width
1.515 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.620 inches
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.063 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches
Fragility Factor
Moderately rugged
Boss Height
0.155 inches
Mounting Surface To Terminal End Distance
2.465 inches
Pole Quantity
2
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One and two linked
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.800 at 300 pct all locations and 4.500 at 300 pct all locations
Inclosure Protection Type For Which Designed
Corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant
Frequency In Hertz
60.0 all locations
Unpackaged Unit Weight
7.400 ounces
Thread Series Designator
Unc
Terminal Type And Quantity
4 threaded stud
FSC
5925 Circuit Breakers
NIIN
004491674
NSN
5925004491674

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
665598B91103-06
Cage Code:
89297
Status:
A
MSDS:
Part Number:
020-400-0000-03
Cage Code:
81541
Status:
A
MSDS:
Part Number:
020-400-0000-00
Cage Code:
81541
Status:
A
MSDS:
Part Number:
APL11-609-6
Cage Code:
81541
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-449-1674
What are the manufacturers of nsn 5925004491674?
Does this nsn 5925004491674 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925004491674
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925004491674 contain any precious metals?
No precious metal content.
Does nsn 5925004491674 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925004491674?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo