Circuit Breaker NSN 5925-00-247-6979

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-247-6979 NSN: 5925-00-247-6979

Features and Characteristics

Body Length
Between 2.490 inches and 2.510 inches
Body Width
Between 2.990 inches and 3.010 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches
Fragility Factor
Moderately rugged
Boss Height
Between 0.130 inches and 0.150 inches
Mounting Surface To Terminal End Distance
Between 2.461 inches and 2.481 inches
Pole Quantity
4
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
8 threaded hole
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, and four linked
Auxiliary Switch Function And Quantity
1 control
Internal Trip Release Configuration
Series trip third location
Thread Size
0.138 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 at 300 pct all locations and 25.000 at 300 pct all locations
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
400.0 all locations
Unpackaged Unit Weight
14.000 ounces
Test Data Document
18876-11152623 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unc
Terminal Type And Quantity
10 threaded stud
FSC
5925 Circuit Breakers
NIIN
002476979
NSN
5925002476979

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
11152623
Cage Code:
18876
Status:
A
MSDS:
Part Number:
AM3336HKMG6-25-A-250-14-400
Cage Code:
74193
Status:
A
MSDS:
Part Number:
73-171-1-MG6
Cage Code:
74193
Status:
A
MSDS:
Part Number:
AM3336HKMG6-25A250V400CPSCURVE14
Cage Code:
74193
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-247-6979
What are the manufacturers of nsn 5925002476979?
Does this nsn 5925002476979 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925002476979
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925002476979 contain any precious metals?
Precious metal content is unknown.
Does nsn 5925002476979 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925002476979?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A