5910-00-115-3601
Electrolytic Fixed Capacitor
Find complete technical information, availability, and procurement data for NSN 5910-00-115-3601 All details are based on official government and industry records to support accurate and compliant procurement.
静電として化学的に形成されたフィルムを持つ、静電容量値を調整または変化できないコンデンサー。 単体、または分離できない2台以上の固定ユニットで構成される場合があります.
w/o mtg facilities, terminal(s) on one end body style, not established reliability indicator, 5.563 inches minimum and 5.687 inches maximum body length, 0.281 inches maximum terminal length, 2.969 inches minimum and 3.031 inches maximum body diameter
特性
以下は、技術データ、材料組成、コンプライアンス情報など、この部品の公式仕様と性能の詳細です。
- ボディ スタイル
- w/o mtg facilities, terminal(s) on one end
- 信頼性の表示器
- not established
- 末端の長さ
- 0.281 inches maximum
- 本体直径
- 2.969 inches minimum and 3.031 inches maximum
- 体長
- 5.563 inches minimum and 5.687 inches maximum
- Ampsの連続的な現在の評価
- 13.4
- ターミナル間の中心への間隔 平行への直径
- 1.234 inches minimum and 1.266 inches maximum
- Schematic の図表の指定器
- no common or grounded electrode(s)
- アノードタイプ
- plain foil
- オウムの最低の作動の臨時雇用者のインピーダンス
- 1.0
- 電気分極
- polarized
- セクションごとの容量の価値
- 21500.000 picofarads single section
- 非処理された作動の臨時雇用者
- -40.0 celsius minimum and 65.0 celsius maximum
- セクションごとのNonderated連続的な電圧評価そしてタイプ
- 45.0 dc single section
- セクションごとの許容範囲
- -10.00 to 100.00 percent single section
- 容量性電極材料
- aluminum
- オウムの参照の臨時雇用者の同等のシリーズ抵抗
- 0.054
- 基準温度でのDC漏れ
- 2.000 microamperes
- 場合の絶縁材材料
- plastic
- 末端のタイプおよび量
- 2 threaded hole
Replaces National Stock Numbers
Below is a list of NSNs that have been officially replaced by the NSN 5910-00-115-3601
| NSN | 名前 | 日付 |
|---|---|---|
| 5910-00-988-6907 | No Name Available | 03/24/1969 |
関連部品と仕様
このNSNには、特定の運用ニーズに合わせて設計されたさまざまな関連部品が含まれています。以下の各項目を確認して、詳細な仕様、機能の詳細、正しい適用と交換に関するガイダンスを見つけてください。
| 部品番号 | 名前 |
|---|---|
| 04774 | Electrolytic Fixed Capacitor |
| 69-1744 | Electrolytic Fixed Capacitor |
| 86F2005MA | Electrolytic Fixed Capacitor |
| CG2152U45G2 | Electrolytic Fixed Capacitor |
Classification Data
Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.
- Type of Item Identification
- Source of Supply
- Demilitarization
- Criticality
- Federal Item Identification Guide
- Precious Metals Indicator
- Pseudo Item Name Code
- Hazardous Material Indicator
- Schedule B Code
- 1 - Full descriptive item identification
- S9E - Defense supply center columbus, columbus, oh 43218
- A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
- X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
- A010B0
- U - Precious metal content is unknown
- 0000008
- P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
- 8532290040
Freight Information
Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.
- Major Organizational Entity
- National Motor Freight Classification Item Number
- National Motor Freight Classification Sub-Item Number
- Uniform Freight Classification Item Number
- National Motor Freight Class Rating
- Water Commodity
- Type of Cargo
- Special Hand
- Air Dimension
- Air Commodity
- National Motor Freight Description
- TX
- 061400
- X
- 34450
- P - 77.5
- 658 - Electrical appliances, small
- Z - No special type of cargo code applicable
- 9 - Other or no special handling required (sh)
- A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
- HZ -
- condensers/parts noi/capacitors
よくある質問(FAQ)
設置手順、動作条件、お手入れ方法、業界規制、一般的な問題に関する洞察を得ることができます。以下のFAQは、次の重要な情報を提供します。 5910-00-115-3601
What is the FSCG of the NSN 5910-00-115-3601?
Does the NSN 5910-00-115-3601 have a Schedule B code assigned?
Does NSN 5910-00-115-3601 require demilitarization?
Does NSN 5910-00-115-3601 contain precious materials?
Does NSN 5910-00-115-3601 contain hazardous materials?
When the NSN 5910-00-115-3601 was assigned to the Federal Catalog?
あなたにおすすめ
カタログから、その他の需要の高いNSNコンポーネントのセレクションをご覧ください。これらの注目の部品は、防衛、航空宇宙、産業分野の調達チームによって頻繁に調達されます。
価格と在庫状況
フォームに記入して、NSNスペシャリストから正確な価格、リードタイム、在庫の詳細を入手してください。