5910-00-045-7508
Electrolytic Fixed Capacitor
Find complete technical information, availability, and procurement data for NSN 5910-00-045-7508 All details are based on official government and industry records to support accurate and compliant procurement.
静電として化学的に形成されたフィルムを持つ、静電容量値を調整または変化できないコンデンサー。 単体、または分離できない2台以上の固定ユニットで構成される場合があります.
0.500 inches nominal terminal length, 2.500 inches nominal body length, w/twist tab mtg, terminal(s) on one end body style, 1.000 inches nominal body diameter, not established reliability indicator
特性
以下は、技術データ、材料組成、コンプライアンス情報など、この部品の公式仕様と性能の詳細です。
- ボディ スタイル
- w/twist tab mtg, terminal(s) on one end
- 信頼性の表示器
- not established
- 末端の長さ
- 0.500 inches nominal
- 本体直径
- 1.000 inches nominal
- 体長
- 2.500 inches nominal
- Schematic の図表の指定器
- electrode(s) grounded to case
- アノードタイプ
- etched foil
- 電気分極
- polarized
- セクションごとの容量の価値
- 40.000 microfarads single section
- 非処理された作動の臨時雇用者
- -30.0 celsius minimum and 85.0 celsius maximum
- 最大動作温度でのDC漏れ
- 5.0 microamperes
- セクションごとのNonderated連続的な電圧評価そしてタイプ
- 450.0 dc single section
- セクションごとの許容範囲
- -10.00 to 50.00 percent single section
- 容量性電極材料
- aluminum
- オウムの参照の臨時雇用者の同等のシリーズ抵抗
- 200.00
- ターミナル 表面処理
- solder
- 場合の絶縁材材料
- plastic
- 末端のタイプおよび量
- 4 tab, solder lug
Replaces National Stock Numbers
Below is a list of NSNs that have been officially replaced by the NSN 5910-00-045-7508
| NSN | 名前 | 日付 |
|---|---|---|
| 5910-00-051-9463 | No Name Available | 11/21/2003 |
| 5910-00-112-7829 | No Name Available | 07/01/1997 |
| 5910-00-270-8978 | No Name Available | 06/01/1992 |
| 5910-00-812-9466 | No Name Available | 09/01/1982 |
| 5910-00-839-5435 | No Name Available | 09/01/1993 |
| 5910-00-851-6118 | No Name Available | 11/24/2003 |
| 5910-00-977-7568 | No Name Available | 08/01/1985 |
関連部品と仕様
このNSNには、特定の運用ニーズに合わせて設計されたさまざまな関連部品が含まれています。以下の各項目を確認して、詳細な仕様、機能の詳細、正しい適用と交換に関するガイダンスを見つけてください。
| 部品番号 | 名前 |
|---|---|
| 0180-0023 | Electrolytic Fixed Capacitor |
| 059-20040-008 | Electrolytic Fixed Capacitor |
| 45RT40 | Electrolytic Fixed Capacitor |
| 501-01394-02 | Electrolytic Fixed Capacitor |
| FP146 | Electrolytic Fixed Capacitor |
| FP146-103009 | Electrolytic Fixed Capacitor |
| FP146103009 | Electrolytic Fixed Capacitor |
| G302857 | Electrolytic Fixed Capacitor |
Classification Data
Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.
- Type of Item Identification
- Automatic Data Processing Point
- Demilitarization
- Criticality
- Federal Item Identification Guide
- Precious Metals Indicator
- Pseudo Item Name Code
- Hazardous Material Indicator
- Schedule B Code
- 1 - Full descriptive item identification
- 0 - Represents items with no adp components
- A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
- X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
- A010B0
- A - Item does not contain precious metal.
- 0000008
- P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
- 8532290040
Freight Information
Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.
- Major Organizational Entity
- National Motor Freight Classification Item Number
- National Motor Freight Classification Sub-Item Number
- Uniform Freight Classification Item Number
- National Motor Freight Class Rating
- Water Commodity
- Type of Cargo
- Special Hand
- Air Dimension
- Air Commodity
- National Motor Freight Description
- XX
- 061400
- X
- 34450
- P - 77.5
- 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
- Z - No special type of cargo code applicable
- 9 - Other or no special handling required (sh)
- A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
- HZ -
- condensers/parts noi/capacitors
よくある質問(FAQ)
設置手順、動作条件、お手入れ方法、業界規制、一般的な問題に関する洞察を得ることができます。以下のFAQは、次の重要な情報を提供します。 5910-00-045-7508
What is the FSCG of the NSN 5910-00-045-7508?
Does the NSN 5910-00-045-7508 have a Schedule B code assigned?
Does NSN 5910-00-045-7508 require demilitarization?
Does NSN 5910-00-045-7508 contain precious materials?
Does NSN 5910-00-045-7508 contain hazardous materials?
When the NSN 5910-00-045-7508 was assigned to the Federal Catalog?
あなたにおすすめ
カタログから、その他の需要の高いNSNコンポーネントのセレクションをご覧ください。これらの注目の部品は、防衛、航空宇宙、産業分野の調達チームによって頻繁に調達されます。
価格と在庫状況
フォームに記入して、NSNスペシャリストから正確な価格、リードタイム、在庫の詳細を入手してください。