5910-00-227-6353
Mica Dielectric Fixed Capacitor
Find complete technical information, availability, and procurement data for NSN 5910-00-227-6353 All details are based on official government and industry records to support accurate and compliant procurement.
1.000 inches minimum terminal length, w/o mtg facilities terminal(s) on one surface body style, not established reliability indicator, 0.360 inches maximum body width, 0.400 inches minimum and 0.450 inches maximum body length
מאפיינים
להלן המפרט הרשמי ופרטי הביצועים עבור חלק זה, כולל נתונים טכניים, הרכב חומרים ומידע על תאימות.
- סגנון גוף
- w/o mtg facilities terminal(s) on one surface
- המונחים:
- not established
- טרמינל אורך
- 1.000 inches minimum
- אורך גוף
- 0.400 inches minimum and 0.450 inches maximum
- גוף Width
- 0.360 inches maximum
- רמת הגוף
- 0.095 inches minimum and 0.180 inches maximum
- מרכז מרחק בין טרמינלים מקבילים לאורכו
- 0.225 inches nominal
- המונחים:
- no common or grounded electrode(s)
- התנגדות למקסימום הפעלה
- 10000.0 megohms
- ערך Capacitance Per סעיף
- 68.000 picofarads single section
- מערכת ההפעלה Nonderated
- -55.0 celsius minimum and 125.0 celsius maximum
- Nonderated Continuous Voltage Index ו- Type Per
- 500.0 dc single section
- מקדם טמפ' של טווח קיבוליות למקטע ב-ppm לדג צלזיוס
- -20.0 to 100.0 single section
- קטגוריה: Tolerance Range
- -5.00 to 5.00 percent single section
- Insulation Resistance At Reference Temp
- 100000.0 megohms
- Dissipation Factor At Reference Temp in Percent
- 0.0020
- טרמינל Surface Treatment
- solder
- חוֹמֶר
- plastic case
- מסמך נתוני בדיקה
- "81349-mil-c-5/18 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
- טרמינל Type & Quantity
- 2 uninsulated wire lead
חלקים ומפרטים קשורים
NSN זה כולל מגוון של חלקים קשורים המיועדים לצרכים תפעוליים ספציפיים. סקור כל פריט להלן כדי למצוא מפרטים מעמיקים, פרטים פונקציונליים והדרכה ליישום והחלפה נכונים.
| מספר חלק | שֵׁם |
|---|---|
| CD15ED680J03 | Mica Dielectric Fixed Capacitor |
| CM05ED680J03 | Mica Dielectric Fixed Capacitor |
| P61-005462-026 | Mica Dielectric Fixed Capacitor |
| W4964168V9 | Mica Dielectric Fixed Capacitor |
Classification Data
Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.
- Type of Item Identification
- Source of Supply
- Demilitarization
- Criticality
- Federal Item Identification Guide
- Precious Metals Indicator
- Pseudo Item Name Code
- Hazardous Material Indicator
- Schedule B Code
- 1 - Full descriptive item identification
- S9E - Defense supply center columbus, columbus, oh 43218
- A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
- X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
- A010B0
- U - Precious metal content is unknown
- 0000005
- P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
- 8532290020
Freight Information
Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.
- Major Organizational Entity
- ZG
שאלות נפוצות
קבל תובנות לגבי נהלי התקנה, תנאי הפעלה, הוראות טיפול, תקנות בתעשייה ובעיות נפוצות. שאלות נפוצות להלן מספקות מידע עיקרי עבור 5910-00-227-6353
What is the FSCG of the NSN 5910-00-227-6353?
Does the NSN 5910-00-227-6353 have a Schedule B code assigned?
Does NSN 5910-00-227-6353 require demilitarization?
Does NSN 5910-00-227-6353 contain precious materials?
Does NSN 5910-00-227-6353 contain hazardous materials?
When the NSN 5910-00-227-6353 was assigned to the Federal Catalog?
זקוק לחומרים מתכלים?
האספקה החיונית אוזלת? עיינו בקטלוג הנרחב שלנו של חומרים מתכלים באיכות גבוהה שנועדו לשמור על הפעילות שלכם במסלול הנכון.
מומלץ עבורך
גלה מבחר של רכיבי NSN אחרים בעלי ביקוש גבוה מהקטלוג שלנו. חלקים מוצגים אלה מגיעים לעתים קרובות על ידי צוותי רכש במגזרי ההגנה, התעופה והחלל והתעשייה.
מחיר וזמינות
מלא את הטופס כדי לקבל תמחור מדויק, זמן אספקה ופרטי מלאי ממומחי ה-NSN שלנו: