1. Inicio /
  2. Catálogo /
  3. Relés y solenoides /
  4. 5945-01-059-0611

5945-01-059-0611

Electromagnetic Relay

Find complete technical information, availability, and procurement data for NSN 5945-01-059-0611 All details are based on official government and industry records to support accurate and compliant procurement.

5945-01-059-0611
Grupo de suministro federal
Electrical and Electronic Equipment Components
Clasificación Federal de Suministros
5945 Relés y solenoides
Número de stock nacional
5945-01-059-0611
Código de nombre del artículo
32512
Fecha de asignación
04/06/1978 (hace 48 años)

right-hand single mounting facility thread direction, 2a single mounting facility thread class, 0.171 inches nominal single mounting facility thread length, 1.397 inches nominal overall height, 0.950 inches maximum overall length

Características

A continuación se muestran las especificaciones oficiales y los detalles de rendimiento de esta pieza, incluidos los datos técnicos, la composición del material y la información de cumplimiento.

Clase de rosca
2a single mounting facility
Dirección de la rosca
right-hand single mounting facility
Longitud de la rosca
0.171 inches nominal single mounting facility
Longitud total
0.950 inches maximum
Altura total
1.397 inches nominal
Anchura total
0.735 inches maximum
Material de la caja
unable to decode
Protección del medio ambiente
dustproof
Factor de fragilidad
moderately rugged
Material de contacto
unable to decode
Tratamiento de superficies de contacto
unable to decode
Cantidad de bobinado
1
Cantidad de bobinas
1
Clasificación de resistencia de CC del devanado
200.0 ohms nominal single winding
Tipo de deber
continuous
Tipo y cantidad de instalación de montaje
unable to decode
Tipo de almacenamiento
general purpose warehouse
Cantidad de hilo por pulgada
48 single mounting facility
Tamaño nominal de la rosca
0.099 inches single mounting facility
Disposición de contacto principal sin apilamientos
2 pole, double throw, one position momentary
Voltaje nominal de funcionamiento y tipo a la temperatura especificada
6.0 volts dc 25 deg celsius single winding
Corriente nominal de carga de contacto principal a voltaje nominal máximo
2.0 amperes ac and 2.0 amperes dc resistive load
Tensión nominal máxima del contacto principal en voltios
115.0 ac and 28.0 dc
Potencia nominal del elemento energizante
2.2 watts
Material precioso y ubicación
contacts silver and contact surfaces gold
Material precioso
gold and silver
Designador de serie de roscas
unc single mounting facility
Tipo de terminal y cantidad
8 tab, solder lug all functions

Partes y especificaciones relacionadas

Este NSN incluye una gama de piezas relacionadas diseñadas para necesidades operativas específicas. Revise cada elemento a continuación para encontrar especificaciones detalladas, detalles funcionales y orientación para la aplicación y el reemplazo correctos.

Número de Parte Nombre
22C00027 Electromagnetic Relay
67SCSX-TBA-3DC Electromagnetic Relay
70R2-VS-3DC Electromagnetic Relay
R10-E1-Y2-S200 Electromagnetic Relay

Classification Data

Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.

Type of Item Identification
4 - Partial descriptive item identification (type 1 concept)
Demilitarization
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Criticality
X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Federal Item Identification Guide
A03300
Precious Metals Indicator
C - Item contains combination of two or more precious metals (silver, gold, platinum).
Pseudo Item Name Code
0032512
Hazardous Material Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Schedule B Code
8536490050

Freight Information

Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.

Major Organizational Entity
TX
National Motor Freight Classification Item Number
061360
National Motor Freight Classification Sub-Item Number
X
Uniform Freight Classification Item Number
34430
National Motor Freight Class Rating
M - 85.0
Less than Car Load Rating
P - 77.5
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
Type of Cargo
Z - No special type of cargo code applicable
Special Hand
9 - Other or no special handling required (sh)
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity
HZ -
National Motor Freight Description
coils/yokes focus/deflection tv

Preguntas Frecuentes

Obtenga información sobre los procedimientos de instalación, las condiciones de funcionamiento, las instrucciones de cuidado, las regulaciones de la industria y los problemas comunes. Las preguntas frecuentes a continuación proporcionan información clave para 5945-01-059-0611

What is the FSCG of the NSN 5945-01-059-0611?
The FSCG of the NSN 5945-01-059-0611 is 5945
Does the NSN 5945-01-059-0611 have a Schedule B code assigned?
Yes, the Schedule B code is 8536490050
Does NSN 5945-01-059-0611 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5945-01-059-0611 contain precious materials?
Item contains combination of two or more precious metals (silver, gold, platinum).
Does NSN 5945-01-059-0611 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5945-01-059-0611 was assigned to the Federal Catalog?
It was assigned hace 48 años, on Thu, Apr 6, 1978

¿Necesita consumibles?

¿Te estás quedando sin suministros esenciales? Explore nuestro extenso catálogo de consumibles de alta calidad diseñados para mantener sus operaciones en marcha.

Electrical Wires

Recomendado para ti

Descubra una selección de otros componentes NSN de alta demanda de nuestro catálogo. Estas piezas destacadas son obtenidas con frecuencia por equipos de adquisiciones en los sectores de defensa, aeroespacial e industrial.

Precio & Disponibilidad

Complete el formulario para obtener precios precisos, plazos de entrega y detalles de existencias de nuestros especialistas en NSN:

FREE

Aviation Suppliers Association Member AS9120-ISO9001 Certification

Piezas populares

Explore nuestras piezas de mayor rendimiento, seleccionadas en función de la demanda del cliente y la frecuencia de adquisición. Todos los listados incluyen especificaciones, disponibilidad y condición actualizadas:

D0010068-2101
4920-01-620-5128
Air Holding Fixture
D0010068-2501
4920-01-620-5129
Nrp,cable Assy Set,
D0010069-2001
4920-01-621-1294
Interface Device Panel
D0010069-2101
4920-01-621-1295
Interface Test Fixture Assembly
D0010069-2103
4920-01-672-3526
Interface Test Fixture Assembly
D0010069-2501
4920-01-620-9361
Interface Dev Cable Assembly Set
D0010069-2503
4920-01-672-3538
Interface Dev Cable Assembly Set
D0010072-2001
4920-01-646-8513
Interface Devic Nrp
D0010072-2101
4920-01-646-8507
Fixture Assembl Nrp
D0010072-2301
4920-01-646-8506
Ai Fixture Assy Nrp
D0010072-2501
4920-01-646-8508
Nrp,cable Assy Set,
D0010073-2001
4920-01-646-3145
Aircra Ifd Otps Nrp
D0010073-2101
4920-01-646-3147
Test Fixture as Nrp
D0010073-2301
4920-01-646-3146
Test Fixture as Nrp
D0010073-2501
4920-01-646-6152
Cable Assembly Nrp