Oscilloscope NSN 6625-00-714-3992

Item Description

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

NSN 6625-00-714-3992 NSN: 6625-00-714-3992

Features and Characteristics

Overall Length
24.000 inches
Overall Height
16.750 inches
Overall Width
13.000 inches
Current Type
Ac
Frequency Rating
60.0 hertz
Accessory Components And Quantity
Adapter, binding post 2, cord, power 1, filter, light 1, lead, test 1, manual, instruction 1, probe, 10-x attenuation 2
Voltage Rating
115.0 volts
Beam Quantity
1
Screen Size
5 in.
Sweep Circuits
Included
Generator Driven Feature
Not included
Sweep Frequency Range
+0.0/+100.0 kilohertz
Trigger Sweep Voltage Amplitude Rating
100.0 volts
Trigger Sweep Polarity Switch
Included
Expanded Sweep
Not provided
Amplifier Deflection Sensitivity Provision
Provided
Vertical Deflection Sensitivity Voltage Rating
50.0 volts peak to peak per centimeter
Horizontal Deflection Sensitivity Voltage Rating
200.0 millivolts any acceptable megahertz
Input Intensity Modulation Feature
Not provided
Plate Direct Connection Deflection Sensitivity Provision
Provided
Direct Connection Vertical Deflection Sensitivity Voltage Rating
7.0 volts any acceptable megahertz
Direct Connection Horizontal Deflection Sensitivity Voltage Rating
30.0 volts peak to peak per centimeter
Frequency Response Rating
Provided
X-axis Frequency Response Rating
1.0 hertz and 240.0 hertz
Y-axis Frequency Response Rating
5.0 hertz and 30000000.0 hertz
Amplifier Input Impedance Rating Provision
Provided
X-axis Input Impedance Rating
1.0 megohms
Y-axis Input Impedance Rating
1.0 megohms
Z-axis Input Impedance Rating
1.0 megohms
Trace Storage Tube
Not included
Camera Recording Device Accommodation
Not provided
Phase
Single
Special Features
For dual trace application, type c-a dc to 24 mc, 15 nano second risetime at 0.05 v/cm to 50.00 v/cm
Fsc Application Data
Oscilloscope, except specially designed
FSC
6625 Electrical And Electronic Properties Measuring And Testing Instruments
NIIN
007143992
NSN
6625007143992

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
PC834900041-5
Cage Code:
38597
Status:
A
MSDS:
Part Number:
1848288
Cage Code:
30003
Status:
A
MSDS:
Part Number:
9975856
Cage Code:
18876
Status:
A
MSDS:
Part Number:
1011931
Cage Code:
56232
Status:
A
MSDS:
Part Number:
545A
Cage Code:
80009
Status:
A
MSDS:
Part Number:
CBTV545A
Cage Code:
80009
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 9030908030
  • NAICS: 334515
  • SITC: 87479
  • Description: Parts and accessories of articles of schedule b subheading 9030.39
  • End Use (Code 21160):
    Measuring, testing, control instruments

Q & A

Frequently asked questions for NSN 6625-00-714-3992
What are the manufacturers of nsn 6625007143992?
Does this nsn 6625007143992 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 6625007143992
A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. it can also be used to indicate any quantity which can be converted into terms of electrical potential. it may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. for items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). see also oscillograph.
Does nsn 6625007143992 contain any precious metals?
No precious metal content.
Does nsn 6625007143992 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 6625007143992?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00357
FIIG:
T320-G
App. Key:
GA
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo