ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Circuit Breaker NSN 5925-01-350-1846

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-01-350-1846 NSN: 5925-01-350-1846

Features and Characteristics

Body Style
Multipole-single actuator type
Body Length
6.310 inches
Body Width
4.120 inches
Body Height
3.380 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
4.880 inches
Center To Center Distance Between Terminals Parallel To Width
1.380 inches
Unthreaded Mounting Hole Diameter
0.188 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.380 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.380 inches
Fragility Factor
Moderately rugged
Boss Height
0.710 inches
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Internal Trip Release Configuration
Series trip all locations
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
Frequency In Hertz
60.0 all locations
Terminal Type And Quantity
6 compression
FSC
5925 Circuit Breakers
NIIN
013501846
NSN
5925013501846

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
13229E1317-2
Cage Code:
97403
Status:
A
MSDS:
Part Number:
TED136150WL-FP
Cage Code:
60969
Status:
A
MSDS:
Part Number:
TED136150WLFA
Cage Code:
60969
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-01-350-1846
What are the manufacturers of nsn 5925013501846?
Does this nsn 5925013501846 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925013501846
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925013501846 contain any precious metals?
No precious metal content.
Does nsn 5925013501846 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925013501846?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo