ORDER BY PHONE (619) 331-9599      Contact Us      Request Quote
facebook
NationalStockNumber.org

Circuit Breaker NSN 5925-00-876-4040

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-876-4040 NSN: 5925-00-876-4040

Features and Characteristics

Body Style
Multipole-multiple actuator type
Body Length
Between 3.709 inches and
Body Width
Between 3.042 inches and 3.062 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches
Center To Center Distance Between Terminals Parallel To Width
Between 1.021 inches and
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.021 inches and
Fragility Factor
Moderately rugged
Boss Height
Between 0.146 inches and 0.166 inches
Mounting Surface To Terminal End Distance
3.239 inches
Pole Quantity
3
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
2000.0 milliamperes ac first location250.0 milliamperes ac second location1.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, and three linked
Auxiliary Switch Function And Quantity
1 control
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.138 inches
Switch Location And Position Designation
External at pole three
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct all locations
Inclosure Protection Type For Which Designed
Moisture resistant
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts
115.0 ac and 28.0 dc
Frequency In Hertz
400.0 all locations
Thread Series Designator
Unc
Terminal Type And Quantity
6 threaded stud
FSC
5925 Circuit Breakers
NIIN
008764040
NSN
5925008764040

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
10105420
Cage Code:
18876
Status:
A
MSDS:
Part Number:
3XAM1516HEMG3-1A416VAC400C12
Cage Code:
L3330
Status:
A
MSDS:
Part Number:
53-210-1MG3
Cage Code:
74193
Status:
A
MSDS:
Part Number:
3XAM1516HKMG3-1-416VAC400HZ2
Cage Code:
74193
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-876-4040
What are the manufacturers of nsn 5925008764040?
Does this nsn 5925008764040 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925008764040
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925008764040 contain any precious metals?
Precious metal content is unknown.
Does nsn 5925008764040 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925008764040?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo