Circuit Breaker NSN 5925-00-776-5062

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-776-5062 NSN: 5925-00-776-5062

Features and Characteristics

Body Style
Single pole type
Bushing Length
Between 0.273 inches and 0.293 inches
Body Length
0.780 inches
Body Width
0.593 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
Between 0.672 inches and 0.734 inches
Mounting Surface To Terminal End Distance
1.812 inches
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac single location and 2.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
800.0 ac single location and 2000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Corrosion resistant and dustproof and explosion proof and fungus resistant and moisture resistant and sand resistant
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Frequency In Hertz
400.0 single location
Unpackaged Unit Weight
1.344 ounces
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator
Uns
Terminal Type And Quantity
2 screw
Specification Data
96906-ms22073 government standard
FSC
5925 Circuit Breakers
NIIN
007765062
NSN
5925007765062

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
MS22073-2-1-2
Cage Code:
96906
Status:
A
MSDS:
Part Number:
MS22073-2 1/2
Cage Code:
96906
Status:
A
MSDS:
Part Number:
MIL-C-5809
Cage Code:
81349
Status:
A
MSDS:
Part Number:
4001-001-205
Cage Code:
81640
Status:
A
MSDS:
Part Number:
200-0094 ITEM 12
Cage Code:
U0ER7
Status:
A
MSDS:
Part Number:
200-0040 ITEM 5
Cage Code:
KCNX0
Status:
A
MSDS:
Part Number:
200-0040/5
Cage Code:
KCNX0
Status:
A
MSDS:
Part Number:
AS58091
Cage Code:
81343
Status:
A
MSDS:
Part Number:
MS22073-2-1/2
Cage Code:
81343
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-776-5062
What are the manufacturers of nsn 5925007765062?
Does this nsn 5925007765062 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925007765062
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925007765062 contain any precious metals?
Precious metal content is unknown.
Does nsn 5925007765062 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925007765062?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo