Circuit Breaker NSN 5925-00-229-3519

Item Description

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

NSN 5925-00-229-3519 NSN: 5925-00-229-3519

Features and Characteristics

Body Style
Rectangular dimensional envelope
Overall Length
17.000 inches
Overall Height
16.188 inches
Overall Width
12.750 inches
Mounting Slot Width
0.187 inches
Body Length
17.562 inches
Body Width
12.750 inches
Body Height
17.000 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
3.625 inches
Unthreaded Mounting Hole Diameter
0.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
11.625 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
10.562 inches
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Features Provided
Adjustable trip release
Maximum Continuous Load Current Rating Per Pole
600.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
35000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Ultimate Trip Time Per Pole In Seconds
56.000 all locations
Reset Method
Electric
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 rotary
Actuator Function
Reset
Actuator Position Designation
At pole one
External Actuator Linkage Arrangement
One, two, and three linked
Auxiliary Switch Function And Quantity
12 alarm
Adjustable Trip Setting Current Range Per Pole In Amps
+280.0/+460.0 ac all locations and +1750.0/+5250.0 ac all locations
Internal Trip Release Configuration
Shunt trip all locations
Reset Actuator Voltage Rating And Type In Volts
208.0 ac
Trip Delay Time In Seconds Per Rated Continuous Current
75.000 at 100 pct all locations and 1000.000 at 100 pct all locations and 46.000 at 200 pct all locations and 300.000 at 200 pct all locations and 40.000 at 300 pct all locations and 150.000 at 300 pct all locations and 34.000 at 400 pct all locations and 90.000 at 400 pct all locations and 28.000 at 500 pct all locations and 65.000 at 500 pct all locations and 10.000 at 1000 pct all locations and 18.000 at 1000 pct all locations
Switch Terminal Type
Threaded stud
Switch Current Rating And Type In Amps
12.0 ac and 24.0 dc
Switch Voltage Rating And Type In Volts
208.0 ac and 46.0 dc
Special Features
Long delay pickup, long time delayband, instantaneous pickup settings adjustable.
Frequency In Hertz
60.0 all locations
Terminal Type And Quantity
6 bus bar
FSC
5925 Circuit Breakers
NIIN
002293519
NSN
5925002293519

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
150-0865
Cage Code:
52151
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-229-3519
What are the manufacturers of nsn 5925002293519?
Does this nsn 5925002293519 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925002293519
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925002293519 contain any precious metals?
No precious metal content.
Does nsn 5925002293519 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925002293519?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A