Circuit Breaker NSN 5925-00-011-7011

Description

NSN 5925-00-011-7011. 3

NSN 5925-00-011-7011 NSN: 5925-00-011-7011

Features and Characteristics

Body Style
Multipole-multiple actuator type
Body Length
2.530 inches
Body Width
3.060 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.940 inches
Center To Center Distance Between Terminals Parallel To Width
Between 0.750 inches and 0.770 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.750 inches and 0.770 inches
Fragility Factor
Moderately rugged
Boss Height
0.150 inches
Mounting Surface To Terminal End Distance
2.522 inches
Pole Quantity
4
Mounting Facility Type And Quantity
8 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic-hydraulic all locations
Trip Release Characteristic
Time delay first locationtime delay second locationtime delay third locationinstantaneous fourth location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, and four linked
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip first locationseries trip second locationseries trip third locationrelay trip fourth location
Thread Size
0.138 inches
Switch Location And Position Designation
Internal at pole three
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct first location and 5.000 at 200 pct first location0.600 at 200 pct second location and 5.000 at 200 pct second location0.600 at 200 pct third location and 5.000 at 200 pct third location
Inclosure Protection Type For Which Designed
Vibration resistant
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
50.0 dc
Frequency In Hertz
400.0 all locations
Thread Series Designator
Unc
Terminal Type And Quantity
10 threaded stud
Specification Data
12436-a15912 government specification
FSC
5925 Circuit Breakers
NIIN
000117011
NSN
5925000117011

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
A15912-006
Cage Code:
12436
Status:
A
MSDS:
Part Number:
73-115-6MG6-30-250VAC400-16
Cage Code:
74193
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8536200040
  • NAICS: 335313
  • SITC: 77252
  • Description: Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5925-00-011-7011
What are the manufacturers of nsn 5925000117011?
Does this nsn 5925000117011 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5925000117011
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does nsn 5925000117011 contain any precious metals?
No precious metal content.
Does nsn 5925000117011 contain any hazardous materials?
No information in HMIRS. Hazardous material unknown.
What is the ESD classification of nsn 5925000117011?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo