Features and Characteristics
Overall Length
2.187 inches
Overall Height
1.710 inches
Overall Width
1.710 inches
Unthreaded Mounting Hole Diameter
0.125 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.271 inches
Vibration Resistance Range In Hertz
+10.0/+500.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.271 inches
Operating Tempurature Range
-55.0/+125.0 degrees celsius
Source Impedance Rating Per Function
50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference
Load Impedance Per Function
50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference400.0 2nd radio interference400.0 3rd radio interference400.0 4th radio interference400.0 5th radio interference400.0 6th radio interference
Operating Current Rating Per Function In Amps
5.0 1st radio interference5.0 2nd radio interference5.0 3rd radio interference5.0 5th radio interference5.0 4th radio interference5.0 6th radio interference
Maximum Voltage Drop Per Function
2.5 volts ac 1st radio interference and 8.0 volts dc 1st radio interference2.5 volts ac 2nd radio interference and 8.0 volts dc 2nd radio interference2.5 volts ac 3rd radio interference and 8.0 volts dc 3rd radio interference2.5 volts ac 4th radio interference and 8.0 volts dc 4th radio interference2.5 volts ac 5th radio interference and 8.0 volts dc 5th radio interference2.5 volts ac 6th radio interference and 8.0 volts dc 6th radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 1st radio interference inductance-capacitance 2nd radio interference inductance-capacitance 3rd radio interference inductance-capacitance 4th radio interference inductance-capacitance 5th radio interference inductance-capacitance 6th radio interference
Input Terminal Manufacturer Code
59610
Input Terminal Identification
Mil-c-26482
Output Terminal Manufacturer Code
59610
Output Terminal Identification
Mil-c-26482
Maximum Tempurature Rise
25.0 degrees celsius
Full Load Insertion Loss Frequencies In Megahertz
0.0 and 0.1 and 1.0 and 10.0 and 100.0 and 1000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels
3.0 and 10.0 and 10.0 and 10.0 and 50.0 and 50.0
Inclosure Type
Hermetically sealed
Mounting Facility Type And Quantity
4 unthreaded hole
Features Provided
Moisture resistant and shock resistant
Functional Terminal Type And Quantity
41 friction w/grounding strap and pin input-output
Maximum Dielectric Withstanding Ac Rms Voltage
1.2 kilovolts at sea level
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 4th radio interference 4th function and 250.0 volts ac 5th radio interference 5th function and 250.0 volts ac 1st radio interference 1st function and 250.0 volts ac 3rd radio interference 3rd function and 800.0 volts dc 4th radio interference 4th function800.0 volts dc 2nd radio interference 2nd function800.0 volts dc 1st radio interference 1st function800.0 volts dc 3rd radio interference 3rd function800.0 volts dc 5th radio interference 5th function250.0 volts ac 6th radio interference 6th function and 800.0 volts dc 6th radio interference 6th function
Maximum Dielectric Withstanding Dc Voltage
1.2 kilovolts at sea level
Body Surface Treatment
Cadmium
Special Features
Forty-one filtered functions with y-type insert position
Precious Material And Location
Contact surfaces gold
Style Designator
Filter connector
FSC
5915 Filters And Networks