Non Wire Wound Variable Resistor NSN 5905-01-073-3622

Item Description

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes resistor (1), variable, nonwire wound, nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, precision.

NSN 5905-01-073-3622 NSN: 5905-01-073-3622

Features and Characteristics

Section Quantity
1
Body Style
Rectangular w/mounting holes/slots
Reliability Indicator
Not established
Terminal Length
0.500 inches
Mounting Hole Diameter
0.088 inches
Shaft Diameter
0.125 inches
Shaft Length
0.062 inches
Body Length
1.250 inches
Body Width
0.281 inches
Body Height
0.312 inches
Shaft Style
Round, slotted
Actuator Type
Single shaft
Effective Electrical Rotation In Deg Angular Rotation
9000.0
Maximum Starting Torque
8.00 inch-ounces
Maximum Running Torque
8.00 inch-ounces
Center To Center Distance Between Terminals
0.700 inches
Lateral Distance Between Mounting Hole Centers
1.000 inches
Mounting Facility Quantity
2
Terminal Location
Lower adjacent side two rows
Mounting Method
Terminal and unthreaded hole
Center To Center Distance Between Terminal Rows
0.100 inches
Electrical Resistance Per Section
100.000 ohms single section
Rotary Actuator Travel In Angular Deg
9000.0
Center To Center Distance Between Center Terminal And Outside Terminal
0.300 inches
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power
125.0 single section
Tempurature Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-70.0/+70.0 single section
Power Dissipation Rating Per Section In Watts
1.0 free air single section
Resistance Tolerance Per Section In Percent
-10.0/+10.0 single section
Actuator Travel Control Feature
Clutch
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power
70.0 single section
Standard Taper Curve Per Section
A single section
Terminal Type And Quantity
3 pin
FSC
5905 Resistors
NIIN
010733622
NSN
5905010733622

Manufacturer Part Numbers

Part numbers registered to this national stock number.
Part Number
Cage
Status
MSDS
Part Number:
2187-100
Cage Code:
91637
Status:
A
MSDS:

Foreign Trade & Schedule B

What is a Schedule B number? Find more information at help.cbp.gov
  • Schedule B Number: 8533390080
  • NAICS: 334416
  • SITC: 77233
  • Description: Wirewound variable resistors, nesoi
  • End Use (Code 20005):
    Electric apparatus

Q & A

Frequently asked questions for NSN 5905-01-073-3622
What are the manufacturers of nsn 5905010733622?
Does this nsn 5905010733622 have a shelf life?
No. This NSN does not have an applicable shelf life.
What is the formal definition of nsn 5905010733622
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. the functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. for items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. for items with step by step variation, see rheostat and resistor, step by step. for tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. excludes resistor (1), variable, nonwire wound, nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, precision.
Does nsn 5905010733622 contain any precious metals?
Precious metal content is unknown.
Does nsn 5905010733622 contain any hazardous materials?
No MSDS. No hazardous material.
What is the ESD classification of nsn 5905010733622?
No known electrostatic discharge.

Identification Group

Item Identification Guide (IIG) and Item Name Code (INC)
INC
FIIG
App. Key
Cond. Code
Status
INC:
37406
FIIG:
A002A0
App. Key:
A
Cond. Code:
1
Status:
A

What do you get when you order from nationalstocknumber.org?

  •   On Time Delivery
  •   Certificate of Conformance
  •   Quality Inspected Parts
  •   Quality Fast Service
ASA Aviation Suppliers Association Member Logo
NQA AS 9120 Suppliers Logo
ITAR Registered International Traffic in Arms Regulations Logo